Australion monitor AMC30 Instrukcja instalacji i obsługi - Strona 5

Przeglądaj online lub pobierz pdf Instrukcja instalacji i obsługi dla Wzmacniacz Australion monitor AMC30. Australion monitor AMC30 12 stron. Amc series 30w/60w/120w/250w mixer amplifiers

6
5
CH 1-3
1
Each channel input section has two inputs: XLR
input - This is a balanced microphone input. It has
an input sensitivity of 1mV. RCA input - This is an
unbalanced line level input. It has an input
sensitivity of 500mV. The two RCA sockets are
summed to mono internally.
2
TAPE OUTPUT
The TAPE output is on unbalanced RCA connectors.
The output level is 150mV into 10kohm at rated
output. The output is dual mono.
The TAPE output is not affected by the MASTER
volume control or the BASS and TREBLE controls.
The TAPE output does not receive the tone signal if
the optional tone generator module is installed.
LINE OUTPUT
3
The LINE output is on a balanced XLR connector. The
output level is 1V into 1k at rated output.
NOTE: When wiring the LINE output as
unbalanced, Pin2 should be wired as hot
and Pin1 should be wired as ground/
shield. Do not wire Pin3.
DIRECT OUT
4
The speaker connections are on the 12 pole terminal
strip. There is a low impedance output (OHM) and
a distributed line voltage output (LINE). 70V out is
available on 115V models. 100V out is available on
230V/240V models.
A M C S E R I E S I N S TA L L AT I O N & O P E R AT I O N M A N U A L
4
7
MINIMUM IMPEDANCE
Distributed Line Output
Low Impedance Output
The output strip comes fi tted with a touch-proof cover held in place by two M3 machine screws
with fl at and spring washers..
5
This is a standard IEC 3 pin socket. It accepts a standard IEC mains cable, provided. The fuse draw
at 5 contains the mains fuse and a spare. The mains fuse is a time lag (slow blow)
HRC 20mm x 5mm ceramic type fuse.
The ratings are:
230V/240V model
115V model
6
(only on 230V/240V models) This switch is used to select the mains voltage for your region.
7
These terminals are for use with an optional tone module (not supplied).
3
AMC30
70V (115V version)
166ohm
100V (230/240V version)
333ohm
(both versions)
4ohm
NOTE: Only connect one output - either Distributed Line or Low
Impedance per channel. Do LowZ and 70/100V at the same time
IEC MAINS INPUT SOCKET
AMC30
Always replace the fuse with one of the same
value and type.
NOTE: Always disconnect power to the amplifi er
before replacing fuses.
VOLTAGE SELECT SWITCH
Always replace the fuse with one of the same
value and type.
(OPTIONAL) TONE MODULE
R E A R PA N E L
2
1
AMC60
AMC120
83ohm
166ohm
4ohm
AMC60
AMC120
0.5A
1.6A
1A
3.15A
AMC250
41ohm
20ohm
83ohm
40ohm
4ohm
4ohm
AMC250
2A
3.15A
4A
6.3A
PA G E 5