5800 Series Transmitter Input Loop Identification
All of the transmitters illustrated below have one or more unique factory assigned input (loop) ID codes. Each of the
inputs requires its own programming zone (e.g., a 5804's four inputs require four programming zones).
WIRELESS INPUT TYPES
"RF" (Supervised RF) Type send periodic check-in
signals, as well as fault, restore and low battery signals.
The transmitter must remain within the receiver's range.
"UR" (Unsupervised RF) Type send all the signals that
the "RF" Type does, but the control does not supervise
the check-in signals. The transmitter may, therefore, be
carried off-premises.
"BR" (Unsupervised Button RF) Type only send fault
signals. They do not send restore or check-in signals.
They will indicate a low battery condition when tested or
activated normally. They can be carried off-premises.
Note: For information on any transmitter not shown
above, refer to the instructions accompanying that
transmitter for details regarding loop numbers, etc.
UL NOTE:
The following transmitters are not intended for
use in UL installations: 5802MN, 5802MN2, 5804, 5804BD,
5814, 5816TEMP, 5819, 5819WHS & BRS, and 5850.
The 5827BD and 5800TM can be used in UL Listed
Residential Burglar installations.
Wireless Key Predefined Default Templates
For 5804
TEMPLATE 1
TEMPLATE 2
TEMPLATE 3
Table of Device Addresses
This Device
RF Receiver
Long Range Radio
4286 Voice Module
Zone Expanders (4219/4229):
module 1 (for zones 09 - 16)
module 2 (for zones 17 - 24)
module 3 (for zones 25 - 32)
module 4 zones 33 - 40
module 5 zones 41 - 48
Relay Modules (4204):
module 1
module 2
module 3
module 4
Keypads:
keypad 1
keypad 2
keypad 3
keypad 4
keypad 5
keypad 6
keypad 7
keypad 8
5800TM Module
** These module addresses apply to VISTA-20P only.
†† Addressable devices are identified by "1" plus the device address when reporting. Enter report code for zone 91 to enable addressable device
reporting (default = reports enabled). See field *199 for addressable device (ECP) 3-digit/2-digit identification keypad display options.
www.PDF-Zoo.com
Loop
Function
Zone Type
1
No Response
2
Disarm
3
Arm Away
4
No Response
1
No Response
2
Disarm
3
Arm Away
4
Arm Stay
1
24-hour audible
2
Disarm
3
Arm Away
4
Arm Stay
Uses Address Reports as †† Enabled By...
00
03
04
07
08
09**
10**
11**
12
13
14**
15**
16
17
18
19
20
21
22
23
28
LOOP 3
LOOP 2
LOOP 1
LOOP 4
YOU MUST
ENROLL THIS
BUTTON
5 8 0 1
ENROLL AS "UR" OR "RF"
LOOP 3
YOU MUST
ENROLL THIS
BUTTON
LOOP 2
LOOP 4
LOOP 1
5 8 0 4
ENROLL
AS "BR"
LOOP 3
LOOP
1
5809
ENROLL AS "RF"
LOOP
1
5808
ENROLL AS "RF"
For 5804BD
23
TEMPLATE 4
22
21
23
23
TEMPLATE 5
22
21
20
7
TEMPLATE 6
22
21
20
100
*56 zone programming: input device type entry
103
automatic if output to long range radio field *29 enabled
104
automatic if phone module access code field *28 enabled
*56 zone programming: input device type entry, then:
automatic if zone no. 9-16 entered as AW type or relay assigned
107
automatic if zone no. 17-24 entered as AW type or relay assigned
108
109
automatic if zone no. 25-32 entered as AW type or relay assigned
automatic if zone no. 33-40 entered as AW type or relay assigned
110
111
automatic if zone no. 41-48 entered as AW type or relay assigned
*79 output device programming: device address prompt:
entered at device address prompt
112
113
entered at device address prompt
entered at device address prompt
114
115
entered at device address prompt
data field programming as listed below:
always enabled, all sounds enabled.
n/a
n/a
data field *190
data field *191
n/a
n/a
data field *192
data field *193
n/a
data field *194
n/a
n/a
data field *195
data field *196
n/a
n/a
automatic
– 15 –
LOOP 2
LOOP
(REED)
2
(REED)
LOOP 1
(TERMINALS)
LOOP
1
ALTERNATE
5 8 1 6 M N
POSITION
ENROLL AS "RF"
FOR LOOP2
5 8 0 2 M N
ENROLL AS "UR" OR "RF"
LOOP
2
(REED)
LOOP 1
(TERMINALS)
LOOP 2
YOU MUST
(TERMINALS)
ENROLL THIS
LOOP 3
BUTTON
(TERMINALS)
5 8 1 9
LOOP 4
ENROLL AS "RF"
LOOP 1
•
• •
• •
•
•
• •
SET
• •
•
5 8 2 7
•
•
HOUSE
SET HOUSE CODE
CODE
5 8 0 4 B D
ENROLL AS "BR"
LOOP
2
(REED)
LOOP 1
(TERMINALS)
(Green)
(Red)
(Yellow)
5 8 1 6
5 8 5 0 ( G B D )
ENROLL AS "RF"
ENROLL AS "RF"
Loop
Function
Zone Type
1
No Response
2
No Response
3
Arm Away
4
Disarm
1
No Response
2
Arm Stay
3
Arm Away
4
Disarm
1
24-hour audible
2
Arm Stay
3
Arm Away
4
Disarm
LOOP
1
(PRIMARY)
2
(AUX. CENTER)
3
(AUX. RIGHT)
5 8 1 7
ENROLL AS "RF"
LOOP
2
(REED)
LOOP 1
(INTERNAL
SHOCK
LOOP 3
SENSOR)
5 8 1 9 S ( W H S & B R S )
ENROLL AS "RF"
5 8 2 7 B D
SET HOUSE CODE
LOOP
1
(MOTION)
5 8 9 0
ENROLL AS "RF"
23
23
21
22
23
20
21
22
7
20
21
22