Smoke & Heat Detector Troubleshooting
NOTE: If the detector indicates a maintenance trouble after the power-up sequence is complete, remove
the battery for 20 seconds and then reinstall.
Caring for the Heat Detector
The Heat Detector is used in areas where a smoke detector may not be feasible, such as a kitchen,
basement, attic or smoking area. The ambient temperature where the Heat Detector is located should
o
not exceed 100 for an extended period of time.
A heat detector employing a Rate of Rise threshold will activate if the temperature rises 15 or more per
minute. If an alarm temperature threshold is available, it is usually set at 135 or 194 An alarm will be
triggered if any threshold is exceeded. Due to the design of the heat detection mechanism, once an alarm
has been triggered, the heat detector must be replaced.
Do not paint the heat detector as this will interfer with the heat sensing mechanism.
Related Topics
Smoke and Heat Detector Battery Replacement
Here is information on how to replace the battery in your device
Finding the Right Peripheral Battery
Here you can locate the correct size and type of battery for your device
System Panel Troubleshooting
Here is information about how smoke and heat alarms may affect your system and keypad, as well as
how to reset your alarm system after an alarm has occurred.
Testing Your System
Here are instructions for placing your system in Test mode, and for removing it from Test mode once the