ADEMCO Rx4GLD Instrukcje instalacji

Przeglądaj online lub pobierz pdf Instrukcje instalacji dla Czujniki bezpieczeństwa ADEMCO Rx4GLD. ADEMCO Rx4GLD 4 stron. Motion detector

ADEMCO Rx4GLD Instrukcje instalacji
®
GENERAL INFORMATION
The Rx4GLD motion detector offers the ultimate in performance with
an unsurpassed combination of detection and false alarm immunity.
Optimal operation is assured with the following advanced features:
¥ Microprocessor-based algorithms for advanced detection & false
alarm immunity processing
¥ Ademco's patented Alternate Polarity Quad detector for
improved false alarm immunity
¥ Immune to pets and other animals up to 45 lbs.
¥ Automatic adaptation to environmental disturbances
¥ Selectable sensitivity
¥ Fast walk rate (10ft/sec)
¥ Advanced dual-slope temperature compensation
¥ Dual channel supervision that reverts to single channel operation
when a failure in the other channel is detected
¥ Form C relay and tamper
¥ Zone-locating walk-test mode
This detector includes a standard wide angle mirror (installed), and an
interchangeable long range/curtain mirror. The optional 1875PA pet
alley mirror is also available. Optional swivel mounting brackets are
available under part number 998SB and Quest-SB2.
CHANGING THE MIRROR
1. Remove front cover by inserting a screwdriver blade in the groove
between the cover and base along the bottom edge and twisting.
2. Spread either or both plastic prongs holding the wide angle
mirror, and remove the mirror. See Fig. 2 for location of prongs.
3. Insert one side of the long range/curtain mirror under a prong, and
snap the other side under the other prong. Make sure the mirror
sides are squarely in their corner rests and are held securely under
the prongs.
NOTE: Mirror surface should be free of dirt, foreign matter and
fingerprints. Use a soft, dry cloth to wipe mirror surfaces, if
required.
MIRROR MASKING
Use the supplied masking strips to produce a protection pattern that
suits the particular requirements of the protected area, or to eliminate
coverage from areas where you anticipate environmental disturbances
that might reduce the PIR's stability (a heater or other heat-producing
object for example).
Simply peel off the appropriate pressure-sensitive strip(s) and apply
over the desired mirror segment(s). Each masked segment eliminates
one zone of protection from the coverage pattern. For convenience,
the masking material may be placed on the white filter material
covering the upper tier, instead of placing it on the mirror itself.
TOP VIEW
(at 7 ft. [2.1m] Mounting Height)
20 ft.
(6m)
10 ft.
(3m)
0
10 ft.
(3m)
20 ft.
(6m)
10 ft.
(3m)
INSTALLATION INSTRUCTIONS
WIDE AREA PATTERN
SIDE VIEW
7 ft.
(2.1m)
3 ft.
(9m)
20 ft.
30 ft.
35 ft.
(6m)
(9m)
(10.7m)
Figure 1. Coverage Patterns
SPECIFICATIONS
Detection Method .................. Passive Infrared
Coverage
Wide Angle Mirror ............... 35' x 45' (10.6m x 13.7m)
Long Range/Curtain Mirror .. 70' x 10' (21.3m x 3m)
Detection Zones
Wide Angle Mirror ............... 9 zones (6 long, 3 short)
Long Range/Curtain Mirror .. 1 zone, 7 tiers
Pulse Processing ................... Standard/ Intermediate And Normal/
Detectable Walk Rate ........... 0.5-10ft/sec (.15-3m/sec)
Mounting Height ................... 7 ft (2.1m) nominal
Indicator ................................ Red LED; enabled/disabled via DIP
Alarm Relay .......................... Form C, 16VDC, 0.13A max. with 15W
Input Voltage ........................ 9-16 VDC with reverse polarity
Current at 12V ....................... 12 mA nominal (non-alarm)
Standby .................................. Power source should be capable of at
Operating Temp. ................... -20°F to 122°F (-29°C to +50°C)
Operating Humidity .............. Up to 95% RH (max.) non-condensing
Dimensions ........................... 2-5/8"W x 4-3/8"H x 1-7/8"D
MASKING NOTE: The segment opposite the zone to be eliminated
is the correct one to mask. For example, to eliminate the rightmost
zone, mask the leftmost mirror segment.
COVERAGE PATTERNS
Figure 1 shows protective patterns for a nominal mounting height of
7 ft (2.1m).
Best coverage will be obtained when the mounting site is selected so
that the likely direction of the intruder is across the pattern of the
detector.
10 ft.
35 ft.
(3m)
(10.7m)
NOTE:
THE DETECTION PATTERN OF THE
DETECTOR IN THE INVERTED POSITION
IS IDENTICAL TO THE PATTERN IN THE
NORMAL MOUNTING POSITION EXCEPT
THAT THE BEAMS TILT UPWARD
MOTION DETECTOR
High sensitivity, both selectable via
DIP switch
Switch
protective resistor
protection
8 mA nom. (alarm, LED disabled)
16 mA nom. (alarm, LED enabled)
16 mA nom. during warm-up
least 4 hours of battery standby
[0°C to +50°C for UL installations]
(67mm x 111mm x 48mm)
CORRIDOR/CURTAIN PATTERN
TOP VIEW (at 7 ft. [2.1m] Mounting Height)
SIDE VIEW
7 ft.
(2.1m)
2.6 ft.
70 ft.
(.8m)
(21.3m)
N8441V1 8/97
4
GLD
3.5 ft.
(1m)
10 ft.
3.5 ft.
(3m)
(1m)