Product Installation Guidelines

TROUBLESHOOTING

PROBLEM
Water is not flowing or has
inconsistent flow
Leak from elbow
Taps are dripping water
Water is leaking from spindle
Water is not flowing from tap
Spindle is difficult to turn
Handle is loose
Flange does not screw down onto
wall surface

WARRANTY

The warranty set forth herein is given expressly and is the only warranty given by the Galvin
Engineering Pty Ltd. With respect to the product, Galvin Engineering Pty Ltd makes no other warranties,
express or implied. Galvin Engineering Pty. Ltd. hereby specifically disclaims all other warranties,
express or implied, including but not limited to the implied warranties of merchantability and fitness for a
particular purpose.
Galvin Engineering Pty Ltd products are covered under our manufacturer's warranty available for
download from www.galvinengineering.com.au Galvin Engineering Pty Ltd expressly warrants that the
product is free from operational defects in workmanship and materials for the warranty period as shown
on the schedule in the manufacturer's warranty. During the warranty period, Galvin Engineering will
replace or repair any defective products manufactured by Galvin Engineering without charge, so long as
the terms of the Manufacturer's warranty are complied with.
The remedy described in the first paragraph of this warranty shall constitute the sole and exclusive
remedy for breach of warranty, and Galvin Engineering Pty Ltd shall not be responsible for any
incidental, special or consequential damages, including without limitation, lost profits or the cost of
repairing or replacing other property which is damaged if this product does not work properly, other
costs resulting from labour charges, delays, vandalism, negligence, fouling caused by foreign material,
damage from adverse water conditions, chemical, electrical or any other circumstances over which
Galvin Engineering has no control. This warranty shall be invalidated by any abuse, misuse,
misapplication, improper installation or improper maintenance or alteration of the product.
© Galvin Engineering Pty Ltd
CAUSE
Shower is blocked with debris.
Insufficient sealant
Ceramic discs are worn or damaged
Tap seat is damaged
O-ring on jumper valve spindle is
damaged or worn
Water is turned off
Aerator or flow regulator is blocked
by debris
Build up of scale on spindle, spindle
worn or o-ring has been damaged
Screw has come loose
Wall bodies are set too far out
Document No.: 001.00.10.16
Version 1, 4 November 2022, Page 7 of 7
RECTIFICATION
Remove debris from shower.
Ensure thread tape has been used
during installation.
Remove and inspect SBA. Remove
debris and/or replace SBA if damaged.
Refurbish tap seat using a reseating
tool.
Replace o-ring
Turn on water
Remove aerator and/or flow regulator
from tap and remove debris. Install an
inline strainer.
Remove cartridge sleeve, clean and
regrease. Replace o-ring. Complete
SBA may need to be replaced.
Tighten handle screw
Re-position tap bodies