AFL HIBUS HCS Series Procedury instalacji - Strona 4

Przeglądaj online lub pobierz pdf Procedury instalacji dla Narzędzia AFL HIBUS HCS Series. AFL HIBUS HCS Series 4 stron. Conductor suspension clamp

5.
Torque Clamping Bolts (item 2) on HIBUS Conductor Suspension Clamp in 5 ft-lb. increments alternating the tightening until 40 ft-lbs.
have been achieved on each.
6.
Install HIBUS Suspension Clamp Assembly to Socket Eye with Attachment Hardware (items 7-9) as shown in Fig. 4-1.
NOTE: When an alternate bolt, nut, and cotter pin arrangement is used for attachment instead of the standard clevis pin and cotter pin,
DO NOT apply a wrench to the nut. The cotter pin should be able to be installed into the bolt when the nut is only finger tight.
7.
Make final visual inspection on HIBUS Conductor Suspension Clamp to ensure that the assembly [groove-bushings (both ends)] and
conductor are not cocked or misaligned, but properly seated.
• 5/8" ATTACHMENT CLEVIS PIN
Fig. 4-1
• 5/8" FLAT WASHER [BOTH SIDES]
(OPTIONAL HARDWARE)
• COTTER PIN
HIBUS CONDUCTOR
SUSPENSION CLAMP
ASSEMBLY
www.AFLglobal.com or (800) 866-7385
SOCKET EYE
CONDUCTOR
HIBUS CONDUCTOR SUSPENSION CLAMP ASSEMBLY AS
INSTALLED. NOTE: SOCKET EYE—TYPE SA SHOWN FOR
INSTALLATION ONLY—CUSTOMER SUPPLIED HARDWARE.