Indesit K3G11/AUS Instrukcja obsługi - Strona 4
Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Kuchenki Indesit K3G11/AUS. Indesit K3G11/AUS 16 stron. Indesit cookers operating instructions
Fig. A
AUS
HOOD
600
Min.
mm.
Gas connection
This appliance is suitable for use with either a
flexible connection or rigid copper connection.
Check The Gas Type
WARNING: Before installation, check that the gas
HOT PARTS
from the factory already set for Natural Gas. To
convert the cooker to LPG (or back to Natural Gas
from LPG), follow the directions later in this section.
Fit regulator supplied for Natural Gas (if applicable)
at rear of appliance, and as close as practicable to
the appliance.
It is recommended that an isolating valve and union
be fitted, to enable simple disconnection for
servicing. These are to be in an accessible location.
.
! Make sure the supply pressure conforms with the
values shown in the table entitled "Caracteristics of
the burners and nozzles".
When the cooker is installed between cabinets
(recessed), the gas connection must be effected by
an approved flexible hose with bayonet fitting (BS
669 Current Edition). The gas inlet for the cookers is
a threaded G 1/2 gas female fitting.
* Only available in certain models.
4
Fig. B
type (natural gas or
LPG/Propane) of the
cooker is suitable for
the gas type available
to the installation. It is
extremely dangerous to
use the wrong gas type
with any appliance, as
fire or serious injury can
result.
This cooker is supplied
Connecting the gas supply
If a flexible hose is used, it should be as short as
possible with a maximum length of 1.5 metres;
• The flexible connection must be approved to
class B or D of AS/NZS1869 as a minimum.
• it should not be bent, kinked or compressed;
• it should not be in contact with the rear wall of the
appliance or in any case with parts which may
reach a temperature of 50°C;
• it should not come into contact with pointed parts
or sharp corners;
• it should not be subject to any pulling or twisting
forces;
• it should be easy to inspect along its entire length
in order to be able to check its condition.
• The supply connection point must be accessible
with the appliance installed.
• The inner diameters of the pipe are as follows:
8 mm for LPG; 13 mm for Natural Gas.
Upon completion of installation, check the gas
circuit, the internal connections and the taps for
leaks using a soapy solution (never a flame). Also
check that the connecting pipe cannot come into
contact with moving parts which could damage or
crush it. Make sure that the natural gas pipe is
adequate for a sufficient supply to the appliance
when all the burners are lit
! Some models can have their gas connection
inverted. It is important to make sure the safety
chain is always situated on the side which
corresponds to the hose holder (Fig. B).
Duplicate Data Plate
Where the data plate is obscured by cabinetry when
the cooker is in the installed position, place a
duplicate data plate on a surface of the cabinetry
adjacent to the cooker.
Electrial Connection
Power supply voltage and frequency: 230-240V a.c.
50/60 Hz.
! ! ! ! ! The supply cable must be positioned so that it
never reaches at any point a temperature 50°C
higher than the room temperature. The cable must
be routed away from the rear vents. Should you
require it, you may use a longer cable, however, you
must ensure that the cable supplied with the
appliance is replaced by one of the same
specifications in accordance with current standards
and legislation.