AEG LAVATHERM 59880 Podręcznik użytkownika - Strona 27
Przeglądaj online lub pobierz pdf Podręcznik użytkownika dla Suszarka AEG LAVATHERM 59880. AEG LAVATHERM 59880 32 stron. Aeg tumble dryer
5) only dryers with the LCD
6) Note: After around 5 hours the drying cycle ends automatically (see Drying cycle complete section).
Changing the bulb for interior lighting
Only use a special bulb which is designed specially for dryers. The special bulb can be ob-
tained from your local service centre.
When the appliance is switched on, the interior lighting switches itself off after 4 minutes
when the door is open.
WARNING!
Do not use standard bulbs! These develop too much heat and may damage the appliance!
Before replacing the bulb, disconnect the mains plug; with a permanent connection: fully
unscrew or deactivate the fuse.
1. Unscrew cover above the bulb (this can be found directly behind the loading aperture,
at the top; refer to "Description of machine" section.)
2. Replace defective bulb.
3. Screw cover back down.
Check the correct positioning of o-ring gasket before screwing back the door light cover.
Do not operate the dryer when missing o-ring gasket on door light cover.
WARNING!
For safety reasons, the cover must be screwed down tightly. If this is not done, the dryer
must not be operated.
MACHINE SETTINGS
Setting
Buzzer per-
manent on/
off
Water hard-
1)
ness
1. Turn the programme dial to any programme.
2. Push at the same time the DRYNESS and SPIN SPEED buttons and hold down
for approx. 5 seconds.
3. The buzzer is by default always off. You can use the buzzer option to activate
or deactivate sound but the machine does not memorise your selection.
1. Turn the programme dial to any programme.
2. Push at the same time the DRYNESS and TIME buttons and hold down for ap-
prox. 5 seconds. The current setting is on the display:
–
low conductivity <300 μS/cm
–
medium conductivity 300-600 μS/cm
–
high Push >600 μS/cm
3. Push the START PAUSE button again and again until you set necessary level.
4. To memorise setting push at the same time the DRYNESS and TIME buttons or
turn knob to OFF position
Implementation
Machine settings
27