Kohler K-1154-HC Instrukcja instalacji - Strona 13
Przeglądaj online lub pobierz pdf Instrukcja instalacji dla Wanny Kohler K-1154-HC. Kohler K-1154-HC 48 stron. Bath whirlpool
Również dla Kohler K-1154-HC: Instrukcja uruchomienia (4 strony)
Turn the jet trim
ring clockwise to
decrease the flow
Turn the jet trim ring
counterclockwise to
increase the flow
12. Confirm Proper Operation
Fill the Whirlpool
NOTE: Please read these steps carefully before you operate your whirlpool.
Position the jet nozzles so they face down toward the basin. Turn the jet trim rings fully counterclockwise.
Fill the whirlpool to a water level at least 2" (5.1cm) above the top of the highest jet.
NOTE: The water temperature in the whirlpool should not exceed 104° F (40° C).
Operating Sequence
Press the air actuator to turn on the whirlpool jets.
Adjust each jet for optimum air/water mixture. Turn the trim ring clockwise to reduce the air flow, and
counterclockwise to increase the air flow.
If equipped with an in-line heater, the heater will engage automatically when the pump is turned on and
will disengage when the pump is turned off. The heater will not turn on if the water temperature exceeds
104° F (40° C).
Press the air actuator a second time to turn off the whirlpool.
NOTE: The optional K-1639 Timer Kit automatically stops the whirlpool after approximately 20 minutes of
operation.
Kohler Co.
Fill with water 2" (5cm)
above the highest jet
Position the jet
nozzles to direct
the water flow as
desired
Press the air actuator to turn on and
off the whirlpool
13
1010564-2-B