Aqua Source Synergy Combi 30 Instrukcja instalacji - Strona 9

Przeglądaj online lub pobierz pdf Instrukcja instalacji dla Systemy filtracji wody Aqua Source Synergy Combi 30. Aqua Source Synergy Combi 30 18 stron. Drum filters

Aqua Source Synergy Combi 30 Instrukcja instalacji
Float is in 'rinse' position, pond pump is on.
Drum is rotating and rinse pump rinses the
screen. If the float remains in this position
for 30 seconds, the electronics will switch to
DRY-RUNNING MODE.
If the float is floating, the system is on stand-by. If the
float is in the lowest position, the process will commence
(drum starts rotating and the rinse pump will rinse the
screen). This will last for 14 seconds.
the float remains in the lowest position (and the pond
If
pump is on) there will be too little water supply from the
pond. The drum will rinse for 30 seconds (standard value)
and then switch to dry-running mode.
This is to protect
your pond pump.
Once the float goes
back to normal
position (it will float
again because
sufficient water flow
into the filter) the
pump will activate
after 5 minutes
(default value).

7.2.6 Control electronics

The control electronics has protection class IP54.
Electrical installations must always comply with the
national and international requirements/guidelines.
Only open the casing of the electronics to
connect the float and magnet contact or to
set the parameters. When connecting the
float and magnet contact, disconnect the
device from the power supply before
connecting it! Changing the parameters is done at own risk
in case the power supply is connected. Take care of
electrical hazard when opening.
The control cabinet must be connected
to an approved, earthed socket. The
electronics must be installed vertically.
The electronics may not be assembled
unprotected during rain. Per connected
side, a maximum of 660 W of auxiliary
equipment may be connected.
Functions of the green button:
Press 1 time:
Quickly press 2 times:
Quickly press 4 times:
Press for 3 seconds:
Press for 8 seconds:
While pressing:
Motor
Rinse pump
Connection 1-2: Float switch OR 5-6 (new model)
Connection 3-4: Lid of magnet contact. Or 6-7 (new
model)( Excludes drums supplied after August
2020)
This is a protection for opening the lid. If the lid is opened,
the drum filter will not rinse ( Pre 2020 models)
Display on white:
Filter is operational
Filter will start to rinse.
Filter and chute will rinse*
Filter into emergency mode
Periodic rinsing.
If float is defective.
Rinse counter reset.
Text message module
sends (test) alarm.
Total number of rinses
visible on screen.
Pond pump