Avtron AV85 Instrukcja obsługi - Strona 9

Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Konwerter mediów Avtron AV85. Avtron AV85 10 stron. 8 1/2 inch c-face mount modular

Avtron AV85 Instrukcja obsługi
THIN-LINE II™ and III™

Application Examples

Applies to all AV85 models, except, wiring options "A", "B", "C", "D", "G", "Q", "R", "S", "T" and "U".
Avtron THIN-LINE II & III encoders provide an alarm signal if maintenance is required under specific circumstances. An
alarm LED indicator is also available. Green indicates power on, red or orange indicates alarm on. Following are application
examples provided to help install the alarm output.
Example 1. Alarm output using +V(OUT). +V(OUT) is equal to +V, the encoder power supply.
ENCODER
FUNCTIONAL DIAGRAM
LINE
DRIVER
NOTE 1
Q5
MMFT6661
Example 2. Alarm Output Using Separate 24 VDC Power Supply and Relay.
ENCODER
FUNCTIONAL DIAGRAM
LINE
DRIVER
NOTE 1
Q5
MMFT6661
ALARM OUTPUT CONNECTION
OUTPUT OPTIONS
"L","W"
"P","Z"
{
1
BLACK
6
RED
CR8
GREEN
2
YELLOW
7
3
BLUE
8
GRAY
4
ORANGE
9
WHITE
5
BROWN
VIOLET
10
OUTPUT OPTIONS
"L","W"
"P","Z"
{
BLACK
1
6
RED
CR8
2
GREEN
7
YELLOW
3
BLUE
8
GRAY
4
ORANGE
9
WHITE
5
BROWN
10
VIOLET
AV85
FUNCTION
COMMON
+V (Encoder Power)
ØA
ØA
ØB
ØB
MARKER
MARKER COMPLEMENT
50 mA MAXIMUM
300 OHM
MIN.
GND
4-16 VDC SOLID STATE RELAY
FUNCTION
COMMON
+V (Encoder Power)
ØA
ØA
POWER
SUPPLY
ØB
ØB
MARKER
MARKER COMPLEMENT
SINK 100 mA MAXIMUM,
WITHSTAND 50 V MAXIMUM
GND
REFERENCED TO COMMON
9
Vcc
OUT
COM
-
24
115 VAC
VDC
+
RELAY