Dell PowerEdge Podręcznik zarządzania systemem - Strona 18

Przeglądaj online lub pobierz pdf Podręcznik zarządzania systemem dla Serwer Dell PowerEdge. Dell PowerEdge 28 stron. Vmware esxi software on servers
Również dla Dell PowerEdge: Podręcznik portfolio (27 strony), Skrócona instrukcja obsługi (6 strony), Instrukcja obsługi (44 strony), Podręcznik użytkownika (20 strony)

Dell PowerEdge Podręcznik zarządzania systemem
Problem
VI Client does not
report memory
error conditions in
PE805
VI Client reports
"Rebuild in
Progress" assert for
all the physical
drives on SAS6i/R
controller
18
Systems Management Guide
Description
Memory health status is shown
as green even if System Event
Log (SEL) files show the error
"Mem ECC Warning: Memory
sensor, transition to critical
from less severe (DIMM_B4)
was asserted".
When a rebuild is occurring for
a single drive on a SAS6i/R
controller, all of the drives are
shown as Rebuild In Progress
Assert.
Storage
Resolution
This is a known issue with this
release of ESXi. Memory failure
errors can be seen from the
"System Event Log (SEL)"
section of the DRAC webpage.
The SEL files can also be
viewed by going to https://<IP
address of ESX Server
host>/host/ipmi_sel. This
might not be the latest SEL
record.
This is a known issue with this
release of ESXi.