Dell EqualLogic PS6110XS Instrukcja obsługi sprzętu - Strona 22

Przeglądaj online lub pobierz pdf Instrukcja obsługi sprzętu dla Przechowywanie Dell EqualLogic PS6110XS. Dell EqualLogic PS6110XS 50 stron. Equallogic ps series iscsi storage arrays with microsoft windows server failover clusters

Dell EqualLogic PS6110XS Instrukcja obsługi sprzętu
Cabling The Dell EqualLogic PS6000/PS6100/PS6500 Storage Arrays
1.
Connect a network cable from the network switch 0 to Ethernet 0 on the control module 1.
2.
Connect a network cable from the network switch 0 to Ethernet 1 on the control module 1.
3.
Connect a network cable from the network switch 1 to Ethernet 2 on the control module 1.
4.
Connect a network cable from the network switch 1 to Ethernet 3 on the control module 1.
5.
Connect a network cable from the network switch 1 to Ethernet 0 on the control module 0.
6.
Connect a network cable from the network switch 1 to Ethernet 1 on the control module 0.
7.
Connect a network cable from the network switch 0 to Ethernet 2 on the control module 0.
8.
Connect a network cable from the network switch 0 to Ethernet 3 on the control module 0.
9.
Repeat steps 1 to 8 to connect the additional Dell EqualLogic PS6000/PS6100/PS6500 storage array(s) to the iSCSI
switches.
NOTE: For PS6100 storage array, having all eight cables in steps 1 through 4 provides highest level of cable
redundancy. It works fine with only four cables. You can skip either step 1 or 5, either step 2 or 6, either step 3 or 7,
and either step 4 or 8.
For more information, see the figures below.
Figure 15. Cabling an iSCSI SAN-Attached Cluster to a Dell EqualLogic PS6000 Storage Array
1. cluster node 1
2. cluster node 2
3. switch 0
4. switch 1
22
5. Dell EqualLogic PS6000 storage system
6. control module 1
7. control module 0