Dell PowerEdge XL 5133-4 Podręcznik dla początkujących - Strona 31

Przeglądaj online lub pobierz pdf Podręcznik dla początkujących dla Przełącznik Dell PowerEdge XL 5133-4. Dell PowerEdge XL 5133-4 38 stron. Dell poweredge m i/o aggregator getting started guide

Configuring and Bringing Up a Stack

After you attach the cables in a stack of Aggregators, follow these steps to
configure and bring up the stack:
1 Connect the terminal to the console port on an Aggregator. Enter the
following commands to access the CLI and configure the base-module
ports for stacking mode:
Login: username
Password: *****
FTOS> enable
FTOS# configure
FTOS(conf)# stack-unit 0 iom-mode stack
Where
stack-unit 0
configuration of a switch.
2 Save the stacking configuration on the 40GbE ports:
FTOS# write memory
3 Repeat Steps 1 and 2 on each Aggregator in the stack by entering the
stack-unit 0 iom-mode stack
4 Reboot each Aggregator by entering the reload command in EXEC
Privilege mode:
FTOS# reload
If the stacked switches all reboot at approximately the same time, the
Aggregator with the highest MAC address is automatically elected as the
master switch. The Aggregator with the next highest MAC address is
elected as standby master.
Tip: You can ensure that a stacked switch becomes the master by rebooting
the switch first, and waiting for it to come up before rebooting the second
switch in the stack.
The Status LED on the Aggregator that is elected as the master switch is
blue. Perform VLAN and other software configuration for the stack by
connecting to the console port on the master unit.
To determine which switch is the stack master, you can also enter the show
system command at the terminal.
defines the default stack-unit number in the initial
command and saving the configuration.
Assembling a Switch Stack
31