^ Position the ceiling plate and align
the notches with the guide line.
Mark the position of the four holes to
be drilled a for securing the ceiling
plate and the position of the hole for
feeding the mains cable b through.
^ If the cooker hood is to be connected
to an external fan motor, also mark
the position of the gap c for its con-
nection cable.
^ Lay the mains cable and the exhaust
ducting Ø 150 mm in the ceiling
space.
If site conditions are not suitable for ø
150 mm ventilation ducting then ø 125
mm ventilation ducting can be used, in
which case a suitable reducing collar is
needed which can be purchased from
your supplier or from the Spare Parts
Dept., (see "Installation – Extraction" for
further details).
^ If the cooker hood is to be connected
to an external fan motor, create the
gap for the connection cable to the
fan motor. Ensure that the diameter is
sufficient to be able to feed through
the 6-pole connector.
22
^ Drill four, 10 mm Ø holes in the ceil-
ing, and insert S10 plugs into the
holes.
The fixings supplied are for use in
concrete ceilings. For other types of
ceiling alternative suitable fixings will
be required. Make sure the ceiling is
stable enough to take the cooker
hood.
^ Secure the ducting to the ceiling
plate using a hose clip.