Connection for air extraction
will need to be addressed. The
exhaust ducting will need to be
suitably insulated.

Condensate trap

In addition to insulating the exhaust
ducting, we recommend that a suitable
condensate trap is also installed to
collect and evaporate any condensate
which may occur.
Condensate traps are available for 125
mm or 150 mm ducting.
 When installing a condensate trap,
ensure that it is positioned vertically
and if possible directly above the
exhaust connection.
The arrow on the housing indicates
the direction of air-flow.
The condensate trap is integrated in
cooker hoods which are designed for
connection to an external motor
(model......EXT).
36

Silencer

To achieve even further reductions in
noise levels, a special silencer (optional
accessory) can be fitted in the ducting
system.
Air extraction
The silencer not only reduces noise
from the motor outside the house, but
also sounds from outside (e.g. traffic
noise). For this reason the silencer must
be positioned as close as possible to
the ducting exit .