If a meter's needle drops to the left limit of the meter's face during operation, this indicates a failure of the related
KT170 tube. You must turn off the M-3000 MK 3 and replace both the fuse (0.5A, 250V, 20mm glass type) for that
tube and the KT170. To replace a fuse, using a screwdriver, simply turn the top of the black fuse cap
counterclockwise (See Figure 6). It will spring out holding the fuse. Replace the fuse, push the fuse cap down and
turn it clockwise; it will lock itself. If you have any questions about doing this, please contact your Allnic dealer for
assistance.
If the AC mains fuse, located at the IEC input, has failed, it can be replaced with the spare fuse provided in the tray in
the IEC mount (See Figure 5). You MUST unplug the M-3000 MK3 to replace an AC mains fuse. Again, if you have any
questions about doing this, please contact your Allnic dealer for assistance.
Of course, you will have to adjust the bias back into the area between the two parallel lines of the meter for a tube
when it is replaced. When replacing a KT170, first turn the bias screw counterclockwise slightly to reduce current,
in case the bias is set too high for the new tube (since the old tube may have required additional bias). Bring the
bias up gradually to the middle between the two lines on the meter.
All consequences of changing or attempting to change tubes are borne by the user unless by express agreement
between the owner and an authorized Allnic representative. Allnic Audio and its authorized representatives are not
liable in any way whatsoever for any injury or loss incurred by the user or for damage to the M-3000 MK 3, any of
its parts, or tubes or replacement tubes resulting from the user changing or attempting to change tubes.

WARRANTY

FOR WARRANTY SERVICE, PLEASE CONTACT YOUR AUTHORIZED ALLNIC DEALER.
All Allnic Audio amplifier products are warranted against materials and manufacturing defects for parts,
excluding tubes, and labour for two (2) years from date of purchase. Tubes are warranted against
materials and manufacturing defects for one (1) year from date of purchase. The warranty is transferable
for the balance of the original purchaser's warranty period, provided, as stated below, no unauthorized
repairs or modifications have been performed on the product. Date of purchase is the date indicated on
the invoice for the product issued by your authorized Allnic Audio dealer.
For the warranty to be valid, a defective product must be returned to your authorized Allnic Audio dealer
for service prior to any unauthorized attempt to repair. Any repair work on an Allnic Audio product not
expressly and specifically authorized by your authorized Allnic Audio dealer will void the warranty on the