INSPECTION
1. Check the air supply pressure
2. Make sure the pump has contact with liquid, which is going to be transferred
(running the pump in a constant dry state is strictly forbidden).
3. Make sure the air supply regulation valve is closed.
4. Use a ground wire for the pump and liquid container, if there is a risk of static
electricity.
USAGE
1.
Open the valve ④, insert device's suction pipe into the liquid.
2.
After making sure the air supply valve is closed, connect the air hose.
3.
Close the valve ④ and open the air supply valve. Then open the valve ④ gradually,
to adjust the delivery rate.
4.
After use, close the air supply valve and unplug the air supply hose. After that, open
[Valve ④ location is marked on the next page]
the valve ④.
TECHNICAL SPECIFICATIONS
Model
Max delivery rate
Max uplift (clear water)
Max temperature
Operated by
KFC103A-N
7.5m
AIR-DRIVEN MOTOR
Air pressure
Air consumption rate
Compressor power:
Connection
5
KFC104A-N
65L/min
8m
60℃
0.3~0.7Mpa
500Nl/min
For continuous operation:
5HP min. Otherwise: 3HP
Air hose φ8