Drain Line Flow Control
Installation Of Bypass
Automatic Bypass
The regeneration cycle lasts approximately 1/2 hour, after which filtered water service will be restored.
During regeneration, untreated water is automatically bypassed for use in the household. Hot water
should be used as little as possible during this time to prevent untreated water from filling the water
heater. This is why automatic regeneration is set for sometime during the night and manual regenerations
should be performed when little or no water will be used in the household.
New Sounds
You may notice new sounds as your water filter operates. The regeneration cycle lasts approximately 1/2
hour. During this time, you may hear water running intermittently to the drain.
Manual Bypass
In the case of emergency, you can isolate your water filter from the water supply using the bypass valve
located at the back of the control. In normal operation the bypass is open with the on/off knobs in line
with the inlet and outlet pipes. To isolate the filter, simply rotate the knobs clockwise (as indicated by the
word BYPASS and arrow) until they lock. You can use your water related fixtures and appliances as the
water supply is bypassing the filter. However, the water you use will not be treated. To resume treated
water service, open bypass valve by rotating the knobs counterclockwise.
Suggested Filter Valve Configuration
Drain Line Flow
Tank Size (Diameter)
8"
9"
10"
12"
Figure 9. Valve Configuration
Figure 10. Injector Assembly
Figure 11.Bypass Exploded View
Control (DLFC)
#4 (3.5 GPM)
#6 (4.0 GPM)
#7 (5.0 GPM)
none