Cisco UCS B440 Uwaga dotycząca instalacji i obsługi - Strona 30
Przeglądaj online lub pobierz pdf Uwaga dotycząca instalacji i obsługi dla Serwer Cisco UCS B440. Cisco UCS B440 33 stron. High performance blade server
Memory and Performance
S e n d d o c u m e n t c o m m e n t s t o u c s - d o c f e e d b a c k @ c i s c o . c o m
Using UCS Manager, perform a graceful shutdown of the server. Without a graceful shutdown, data may
Step 1
be permanently lost.
Remove the blanking plate, if present, from the BBU bay at the right of the server.
Step 2
Slide the BBU unit in partially, and align the ejector lever as shown in
Step 3
Figure 18
.
Continue pressing the BBU in until the ejector lever folds below the carrier tray. The BBU rear connector
Step 4
should automatically seat with the RAID controller at its rear.
Secure the BBU in place by tightening the captive screw with a #2 Phillips screwdriver.
Step 5
Figure 19
Cisco UCS B440 High Performance Blade Server Installation and Service Note
30
Slide in the BBU
Tighten the Captive Screw
Figure
18.
OL-22475-01