How to Configure Clear Channel T3/E3 Controllers and Channelized T1/E1 Controllers
Restrictions
•
SUMMARY STEPS
1.
2.
3.
4.
5.
6.
7.
8.
9.
DETAILED STEPS
Command or Action
Step 1
configure
Example:
RP/0/RSP0/CPU0:router# configure
Step 2
controller e3 interface-path-id
Example:
RP/0/RSP0/CPU0:router(config)# controller t3
0/1/0/0
Step 3
clock source {internal | line}
Example:
RP/0/RSP0/CPU0:router(config-e3)# clock source
internal
Step 4
cablelength feet
Example:
RP/0/RSP0/CPU0:router(config-e3)# cablelength
250
Cisco ASR 9000 Aggregation Services Router Interface and Hardware Component Configuration Guide
458
Configuring Clear Channel T3/E3 and Channelized T3 and T1/E1 Controllers on the Cisco ASR 9000 Series Router
E3 is not supported on the 4-Port Channelized T3/DS0 SPA.
configure
controller e3 interface-path-id
clock source {internal | line}
cablelength feet
framing {g751 | g832}
national bits {disable | enable}
no shutdown
end
or
commit
show controllers e3 interface-path-id
Purpose
Enters global configuration mode.
Specifies the E3 controller name in the notation
rack/slot/module/port and enters E3 configuration mode.
(Optional) Sets the clocking for individual E3 links.
Note
The default clock source is internal.
When configuring clocking on a serial link, you
Note
must configure one end to be internal, and the other
end to be line. If you configure internal clocking on
both ends of a connection, framing slips occur. If
you configure line clocking on both ends of a
connection, the line does not come up.
(Optional) Specifies the distance of the cable from the
router to the network equipment.
The default cable length is 224 feet.
Note