Epson ProofPlus TM-H6000III Podręcznik rozwoju - Strona 32

Przeglądaj online lub pobierz pdf Podręcznik rozwoju dla Skaner Epson ProofPlus TM-H6000III. Epson ProofPlus TM-H6000III 32 stron. Ecc printer
Również dla Epson ProofPlus TM-H6000III: Instrukcja obsługi produktu (27 strony), Broszura (2 strony), Specyfikacje (2 strony), Broszura (6 strony), Podręcznik użytkownika (32 strony), Podręcznik rozwoju (26 strony), Podręcznik rozwoju (45 strony), Podręcznik (10 strony), Podręcznik użytkownika (29 strony)

Epson ProofPlus TM-H6000III Podręcznik rozwoju
The power is
Upon completion of EndInsertion
turned
off
method, the following retune values
during insertion
are set:
RC: OPOS_SUCCESS
RCE: 0
The result of data analysis is
notified by ErrorEvent.
RC and RCE of the ErrorEvent are as
follows:
When power OFF state is detectable
RC: OPOS_EX_NOHARDWARE
RCE: 0
When
detectable
RC: OPOS_E_OFFLINE
RCE: 0
The
paper
is
Upon completion of EndInsertion
removed during
method, the following retune values
insertion
are set:
RC: OPOS_SUCCESS
RCE: 0
The result of data analysis is
notified by ErrorEvent.
RC and RCE of the ErrorEvent are as
follows:
RC: OPOS_E_EXTENDED
RCE: OPOS_EMICR_NOCHECK
The
line
is
Upon completion of EndInsertion
turned off during
method, the following retune values
insertion
are set:
RC: OPOS_SUCCESS
RCE: 0
The result of data analysis is
notified by ErrorEvent.
RC and RCE of the ErrorEvent are as
follows:
RC: OPOS_E_OFFLINE
RCE: 0
The timeout time
Upon completion of EndInsertion
is up
method, the following retune values
are set:
RC: OPOS_SUCCESS
RCE: 0
The result of data analysis is
notified by ErrorEvent.
RC and RCE of the ErrorEvent are as
follows:
RC: OPOS_E_ILLEGAL;
RCE: OPOS_EX_TIMEOUT
power
OFF
state
28
APPLICATION DEVELOPMENT GUIDE
MICR (EPSON TM Series)
Version 3.00 Feb. 2019
Upon completion of EndInsertion
method, the following retune values
are set:
When power OFF state is detectable
RC: OPOS_E_ILLEGAL
RCE: OPOS_EX_BUSY
When
power
detectable
RC: OPOS_E_OFFLINE
RCE: 0
There is no notification by event.
is
not
Upon completion of EndInsertion
method, the following retune values
are set:
RC: OPOS_E_EXTENDED
RCE: OPOS_EMICR_NOCHECK
There is no notification by event.
Upon completion of EndInsertion
method, the following retune values
are set:
RC: OPOS_E_OFFLINE
RCE: 0
There is no notification by event.
Upon completion of EndInsertion
method, the following retune values
are set:
RC: OPOS_E_ILLEGAL;
RCE: OPOS_EX_TIMEOUT
There is no notification by event.
OFF
state
is
not