Whirlpool 4LEC7646EN0 Instrukcja instalacji - Strona 3
Przeglądaj online lub pobierz pdf Instrukcja instalacji dla Suszarka Whirlpool 4LEC7646EN0. Whirlpool 4LEC7646EN0 7 stron. Electric and gas dryers
Również dla Whirlpool 4LEC7646EN0: Instrukcja obsługi i konserwacji (27 strony)
42-318
L107.6
:m)
For proper drying performanct
The location
must provide:
Protection
from
weather
and water:
Do not store
or use dryer where
it will be exposed
to water
and
weather.
L/Room
temperature
above
45°F (7.2"C):
If room
temperature
is below
45°F (7.2"
C), automatic
I
cvcles mav not shut off.
Explosion Hazard
Id'
'
Level floor:
Maximum
slope under
entire
dryer
Keep flammable materials and vapors away
from dryer.
Place dryer at least 18 inches above the
floor for a garage installation.
Failure to do so can result in death,
explosion, fire, or burns.
should
not be more than
i inch (2.5 cm). (Ii slope
is greater
than
1' (2.5 cm), install
Extended
Dryer
Feet Kit, Part No. 279810.)
Clothes
may not tumble
properly
and automatic
sensor cycles may not
operate
correctly
if dryer
is not level.
/Sturdy
floor
to support
dryer weight
of 150
pounds
(68 kg).
'
(/Exhaust
to outdoors:
To prevent
large amounts
of
lint and moisture
from
accumulating
and to
maintain
drying
efficiency,
exhaust
dryer
to
outdoors.
L/observe
all governing
codes
and ordinances.
(/consider
spacing
requirements
for companion
C/check
code
requirements:
Some codes limit or
appliances.
do not permit
installation
of clothes
dryers
in
L/properly
install
dryer.
garages,
closets,
mobile
homes
or sleeping
*from floor
\v
quarters.
Contact
your
local building
inspector.
C/m&e
sure
you
have
evm-vthinn
na~nccxrw
fnr
1
proper
installation.
with dryer feet
extended
1
Ycomply
with
the installation
specifications
and
dimensions.
(/contact
a qualified
installer
to insure
that the
inch (2.5 cm)
electrical
installation
meets all national
and local
codes and ordinances.
1
1
w
-*=__-.
"=x I
dryer exhaust vent
y
It is your responsibility to:
Recessed area/closet installation
Closet/confined area installation
Recessed area installation
If a closet
door
is installed:
The
minimum
unobstructed
air openings
are
required.
Louvered
doors with equivalent
air openings
are acceptable.
The dryer
should
be exhausted
to the outside
for best performance.
If dryer
is not exhausted
outside,
you must
install
Exhaust
Deflector
Kit. Part No. 3391278.
klre Hazard
front view
Exhaust dryer outside if installed in a closet.
Use Exhaust Deflector Kit #3391278 if
installed in a recessed area.
Failure to follow this instruction could
result in a fire.
NOTE:
No fuel-burning
appliances
may be
installed
in the same closet
as a dryer.
l
If codes permit,
dryer
may be installed
in a
(1
recessed
area or closet
using dimensions
shown.
* Dimensions
are in inches
and are the
minimum
allowable.
side view
available
from
your dealer.
L
3' (7.6 cm)
3' (7.6 cm)
Lu
,:;.,il
F=-
front view
l
Additional
spacing
should
be considered
for
ease of installation
and servicing.
Companion
appliance
spacing
should
also be considered,
** Minimum
top and bottom air openings for closet door.
*** External exhaust elbow requires additional
space.
l
*** Wall .door and floor molding
may require
addItIonal
spacing.
Door clearance
Location
must be large enough
to fully open dryer
door.
3-710"
(9.8
cm)
Electrlcal Shock Hazard
Electrical ground (earth) is required on this
Do Not reuse old power supply cord.
dryer.
Check with a qualified electrician to be sure
Do Not ground (earth) to a gas pipe.
dryer is properly grounded (earthed).
Do Not change the power supply cord plug.
lf it does not fit the outlet, have a proper
Do Not connect plug end of power supply
cord into a live receptacle before connecting
outlet installed by a qualified electrician.
Do Not have a fuse in the neutral or
grounding circuit.
Do Not use an extension cord with this
J dryer.
power supply cord to dryer terminal block.
Failure to follow these instructions could
result in death or serious injury.
Important: Observe all governing codes and
ordinances.
If codes permit
and a separate
grounding
(earthing)
wire
is used, it is recommended
that
a qualified
electrician
determine
that the grounding
(earthing)
path
is adequate.
A two-wire,
single
phase,
220-volt,
60-Hz,
AC-only,
electrical
supply
is required
on a
separate
30-ampere
circuit,
fused on both
sides
of the line. A time-delay
fuse or circuit
breaker
is
recommended.
THE DRYER MUST BE CONNECTED
WITH
COPPER WIRE ONLY.
The dryer
may be connected
directly
to the
fused disconnect
or circuit
breaker
box through
flexible,
armored
or non-metallic
sheathed
copper
cable. Allow
two or three feet
(61-91
cm) of slack in the line between
the wall
and the dryer so that it can be moved
if
servicing
is ever necessary.
A conduit
connector
must be provided
at each end of the power
supply
cable (at the appliance
and at the
junction
box).
Wire sizes (COPPER WIRE ONLY)
and connections
must conform
with
the rating
of the appliance
(30 amperes).
Grounding (earthing) instructions
This appliance
must be connected
to a
grounded
(earthed)
metal,
permanent
wiring
system;
or an equipment-grounding
(earthing
conductor
must be run with
the circuit
conductors
and connected
to the equipment-
grounding
(earthing)
terminal
or lead on the
appliance.
-
Panel A