INSTALLATION INSTRUCTIONS
P i pc:;ssst
Before making cutouts, make sure there is proper clearance
within the ceiling or wall for the exhaust vent.
When cutting or drilling into the ceiling or wall, do not
damage electrical wiring or other hidden utilities.
Check that all installation parts have been removed from the
shipping carton.
1. Disconnect
power.
2. Determine which venting method to use: roof or wall exhaust.
Excessive
Weight Hazard
Use two or more people to move and install
range hood.
Failure to do so can result in back or other injury.
5.
Pull the spring clip to release the blower motor assembly.
Remove the blower motor assembly from the housing and
place it on a covered surface.
A
B
C
3. Using 2 or more people, move the in-line blower motor
system to the mounting location.
Prepare for Mounting
the In-line Blower System
The in-line blower system must be fastened to a secure structure
of the roof, ceiling, wall, floor, or new or existing frame
construction.
The 4 holes on either the inlet (bottom) side or the
outlet (top) side of the blower must be used to mount the in-line
blower system to the structure.
NOTE: The mounting hole locations must span the studs.
Additional stud framing may be required. Plywood may be used
to span open areas between ceiling joists or roof rafters to aid
installation. This structure must be strong enough to support the
weight of the in-line blower system (50 Ib [22.6 kg] mini.
Prepare the In-line Blower System
1. Remove the 10 screws from the front cover of the in-line
blower motor housing and set them aside.
2. Remove the front cover of the in-line blower motor housing
and set it aside.
NOTE: To make the in-line blower motor housing easier to
mount, the blower motor assembly can be removed. If you do not
want to remove the blower motor assembly, proceed to the
"Installation
of the In-line Blower System" section.
3. Disconnect
the motor electrical plug from the blower motor
assembly.
4. Remove the screws that secure the blower motor assembly
to the in-line blower housing and set them aside.
A. Front cover
B. Blower mounting screws
C. Spring clip
D. Motor electrical plug
Installation
of the In-line Blower System
NOTE: The blower motor housing can be mounted using 4 holes
from either the inlet side or the outlet side of the blower.
A
A
A. Mounting holes
1. Position the in-line blower motor housing in its mounting
location and mark the 4 mounting hole locations.
2. Drill 4 mounting pilot holes using a ¾d' (0.5 cm) drill bit.
3. Attach the in-line blower motor housing to the mounting
location with four 6 x 80 mm mounting screws and flat
washers.
6