Whirlpool UXL6036YSS0 Instrukcje instalacji oraz instrukcja obsługi i konserwacji - Strona 5
Przeglądaj online lub pobierz pdf Instrukcje instalacji oraz instrukcja obsługi i konserwacji dla Okap wentylacyjny Whirlpool UXL6036YSS0. Whirlpool UXL6036YSS0 36 stron. 36" (91.4 cm) and 48" (121.9 cm) hood liner
Product Dimensions
/
/
_----_
18" (45.7 crn) for 36" models
/
24" (61.0 crn) for 48" models
27%" (70.1
•
Do not use 4" (10.2 cm) laundry-type wall caps.
•
Use metal vent only. Rigid metal vent is recommended.
Plastic or metal foil vent is not recommended.
•
The length of vent system and number of elbows should be
kept to a minimum to provide efficient performance.
For the most efficient
and quiet operation:
•
Use no more than three 90 ° elbows.
•
Make sure there is a minimum of 24" (61.0 cm) of straight
vent between the elbows if more than 1 elbow is used.
•
Do not install 2 elbows together.
•
Use clamps to seal all joints in the vent system.
•
Use caulking to seal exterior wall or roof opening around the
cap.
riling
Vent system must terminate to the outdoors.
Makeup
air
Do not terminate the vent system in an attic or other enclosed
Local building codes may require the use of makeup air systems
area.
when using ventilation systems greater than specified CFM of air
movement. The specified CFM varies from locale to locale.
Consult your HVAC professional for specific requirements in your
area.
Venting Methods
Typical Internal Blower Motor System Venting Installations
A 10" (25.4 cm) round vent system is needed for installation (not
included). The hood exhaust opening is 10" (25.4 cm) round.
NOTE: Flexible vent is not recommended.
Flexible vent creates
back pressure and air turbulence that greatly reduce
performance.
Vent system can terminate either through the roof or wall. To vent
through the wall, a 90 ° elbow is needed.
Roof Venting
Wall Venting
•
The size of the vent should be uniform.
Cold weather
installations
An additional back draft damper should be installed to minimize
backward cold air flow and a thermal break should be installed to
minimize conduction of outside temperatures
as part of the vent
system. The damper should be on the cold air side of the thermal
break.
The break should be as close as possible to where the vent
system enters the heated portion of the house.
....
......
A. 10" (25.4 cm) round vent
B. Roof cap
A. 10" (25.4 cm) round vent
B. Wall cap