Alemite 7149-4 Series Instrukcja serwisowa - Strona 3

Przeglądaj online lub pobierz pdf Instrukcja serwisowa dla Pompa wodna Alemite 7149-4 Series. Alemite 7149-4 Series 14 stron. Hand operated bucket pumps

Alemite 7149-4 Series Instrukcja serwisowa
SER 7149-4
To assemble the basic Bucket Pump Model 7149-4, proceed as follows (see Figure 2):
1. Attach link 322092-7 to pump body 322115-6 (see Figure 12) with pin 322109-2 and secure
with cotter pin 172212-14.
2. Attach lever 322418-2 to link with pin and secure with cotter pin.
3. Attach lever to pump plunger with stud 322428 and wing nuts 79882 through one of the three
holes provided (see adjustment instructions on page 7).
4. See further instructions for specific model.
Figure 4: Model 322434 Hose Assembly (for Models 7149-A4 and 7149-H4)
MODEL 7149-A4 (Figures 3 and 4):
Thread hose assembly 322434 into check valve 317210 and tighten.
Alemite, LLC
ASSEMBLY
Figure 3: Model 7149-4 Bucket Pump
3
Hand Operated Bucket Pump
Revision (8/06)