Alemite 7785-MA Instrukcja serwisowa - Strona 7

Przeglądaj online lub pobierz pdf Instrukcja serwisowa dla Pompa wodna Alemite 7785-MA. Alemite 7785-MA 14 stron. High-pressure grease pump

Alemite 7785-MA Instrukcja serwisowa
High-Pressure Grease Pump
Overhaul
NOTE: Refer to Figure 2-A and 2-B for
component identification on all overhaul
procedures.
Prior to performing any maintenance procedure, the
following safety precautions must be observed. Personal
injury may occur.
WARNING
Do not use halogenated hydrocarbon
solvents such as methylene chloride or 1,1,1-
trichlorethane in this pump. An explosion can
result when aluminum and/or zinc-plated parts in
the pump come in contact with halogenated
hydrocarbon solvents.
Release all pressure within the system prior to
performing any overhaul procedure.
• Disconnect the air supply line from the
pump motor.
• Into an appropriate container, operate the
control valve to discharge remaining
pressure within the system.
Never point a control valve at any portion of your
body or another person. Accidental discharge of
pressure and/or material can result in injury.
Read each step of the instructions carefully.
Make sure a proper understanding is achieved
before proceeding.
Removal
NOTE: These model pumps are used in
numerous applications and are mounted
accordingly. The following procedures
consider the pump assembly to be
mounted to a container with a cover.
1. Remove the cover and pump assembly from its
container.
2. Remove the four bolts that secure the pump
assembly to the cover.
IMPORTANT: Remove the follower from
the bottom of the container.
Alemite, LLC
1-800-548-1191-http://[email protected]
Disassembly
1. Unscrew Adapter (5) from Air Motor Assembly (2).
2. Remove Washer (8) and rubber Bushing (9).
Separate Pump Tube from Air Motor
3. Clamp the motor housing horizontally in a vise.
4. Loosen Jam Nut (23) that secures the Pump Tube
assembly to the Air Motor Assembly.
CAUTION
Support the Pump Tube assembly during removal.
Damage to components can occur.
5. Unscrew Pump Tube (28) [with attached components]
from the Air Motor.
6. Pull on the Pump Tube to expose Coupling (25).
7. Remove upper Spring Clip (26) that secures Pump Tube
Rod (27) to Coupling (25).
8. Unscrew the Coupling from the air motor piston rod.
• Rotate the entire Pump Tube assembly.
Pump Tube Upper Packing
9. Unscrew Cap Screws (13) that secure Body (12) to the
Air Motor.
• Do not remove the Cap Screws from the Body.
10. Remove the Body from the Air Motor.
• Use the Cap Screws as levers.
11. Position the Body on the bench with the larger diameter
facing upward.
12. Remove aluminum Gasket (21), Washer (22), and
additional Gasket (21) from the Body.
13. Remove Spacer (20), Washer (19), and Seal (18).
14. Remove Lantern Ring (17) with Seal (16), and
Spacer (15).
• Remove the Seal from the Lantern Ring.
15. Remove O-Ring (14), O-ring (10), and O-Ring (11) from
the Body.
Pump Tube
16. Clamp the pump tube assembly at Adapter (43) securely
in a soft-jaw vise.
7
SER 7785-A5
Revision (11-08)