AERF WIRELESSBAND 2.F Instrukcja obsługi - Strona 6

Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Sprzęt sieciowy AERF WIRELESSBAND 2.F. AERF WIRELESSBAND 2.F 6 stron.

GB
12. TRANSMITTER OPTIONS SELECTOR
ON
IN 1 SAFETY
1
2
3
EDGE TYPE
ON
1
2
3
ON
SAFETY EDGE
1
2
3
TYPE (INPUT 2)
ON
1
2
3
ON
TRANSMITTER
1
2
3
FREQUENCY
ON
TECHNICAL SPECIFICATIONS
Receiver supply voltage
Transmitter supply voltage
Transmitter inputs
Transmitter Inhibition input type
Receiver memory
Receiver Output
Receiver test inputs
Type
Receiver Power consumption
Ball pressure test (IEC 695-10-2)
Pollution degree
Protection class (IEC 60529)
Frequency Channels
Range
Working temperature
Software
Rated transient over voltage
Transmitter power consumption
Maximum screw force
Machine Security Normative
Reaction time
CE DECLARATION OF CONFORMITY
Aplicaciones electrónicas y de Radiofrecuencia S.L Pol. Sot dels Pradals C/ Sot dels pradals, 4
08500 Vic (Barcelona) B61840732 DECLARES, under her own responsibility that product complies
with the requirements of the R&TTE 99/05/CE European parliament directive of March 9th 1999.
This directive was transposed to the Spanish legislation by means of Real Decree 1890/2000 in
November 20th of 2000. For more information visit the website www.aerf.eu
WIRELESSBAND 2.F
Resistive (8k2 )
Mechanical (0Ω)
Resistive
supply from receiver (OFF)
configuration
Optical
configuration
869,85 Mhz (setting MUST
RECEIVER
match that of receiver)
ON
868,95 Mhz (setting MUST
match that of receiver)
supply from receiver (ON)
12/24 AC/DC
2x AA lithium battery 3.6V
Selectable by dip-switch and prog.
1 Resistive / contact /optical
1 Resistive / contact
Power free contact
7 transmitters per channel
2 Relay, micro disconnection 1B
or power free contact
2
- 12/24V AC/DC , contact, open collect.
0.5 W - 12 V / 1,2 W - 24 V
PCB (125ºC) WRAP (75ºC)
2
Ip55
868.95MHz & 869.85MHz
100m
-20ºC to +55ºC
Class A
330V
Transmitting 17mA / stand by 16uA
0,4 Ncm
13849-2008 PL-C
Category 2, with TEST
60 ms
(according TÜV test report AV86368T
Certificate nº M6A 14 12 90800 001)
(see point 10.2)
RECEIVER
ON
+
5X
FLASH
1
2
3
4
5
Optical sensor power
IN2 - Resistive
Safety Edge
(default)
(see point 10.2)
+
2X
FLASH
1
2
3
4
5
Optical sensor power
IN2 - Optical
Safety Edge
WARNING!!
- Installation, start-up, modification and retrofitting of
the system may only be carried out by a qualified person.
-
Switch off the operating voltage before working on the system.
- The system doesn't have fuse protection. Is
recommended include exterior protection minimum
100mA and maximum 250mA.
TRANSMITTER
ON
Input 2 Resistive
+
1
2
3
ON
Input 2 Mechanical
1
2
3
TRANSMITTER
Input 2 Optical
ON
Inhibition in Receiver
+
and Transmitter
1
2
3
ON
Not used
1
2
3
RoHS
6 - 6