Aerial AD 770 Instrukcja obsługi - Strona 11
Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Osuszacz powietrza Aerial AD 770. Aerial AD 770 15 stron.
Type
Air volume
Power
consumption
Noise level
Refrigerant (charge see
type plate)
Capacity / power consumption at
30°C / 80%
27°C / 60%
20°C / 60%
10°C / 70%
dimensions
weight
8.Service & maintenance
ATTENTION
When performing any repair or maintenance, the general safety rules and
provisions must be adhered to!
In order to guarantee a troublefree function of the dryer the device should be
cleaned regularly. The following procedure is recommended:
Ø Switch OFF the air dryer
Ø Disconnect mains cable
Ø Remove filter holder
Ø Remove filter for cleaning or disposal
Ø Dismount front panel
Ø Blow out device cautiously with compressed air. (wear protective goggles!) In
this case, it might ensure that all components are cleaned. (Compressor,
evaporator, condenser, ect.)
Ø Check hose connector and connected hose
Ø Mount front panel
Ø Clean case with moist cloth. Do not use aggressive Detergent
Ø Insert new or cleaned filter, Insert filter holder
Ø Put main plug into the socket
Ø Switch on dehumidifier.
AD 740
cbm/h
710
Max.
800
Watt
dB(A)
53
R407c
l/24h
42,0
Watt
800
l/24h
26,8
Watt
700
l/24h
19,2
Watt
600
l/24h
11,0
Watt
500
mm
880 x 520 x 495
kg
40
Page 11 of 15
AD 750
AD 770
710
900
900
1015
53
53
R407c
R134a
55,0
70,8
900
1015
34,1
44
780
840
24,5
28,6
660
710
14,0
17,5
560
558
1000 x 640 x 580
42
55
AD 790
1400
1700
65
R407c
90,0
1700
58,3
1400
41,0
1150
20,0
950
61