Solar charge controller MAX series User Manual
4. Conection and grounding
4.1 Conection
We strongly recommend connecting a fuse directly to the battery terminal to protect from any short ciruct
in the battery
circuit. PV-modules generate current whenever light shines on them. The generated current
is directly proportional to the light intensity. Even low levels of light, will deliver the PV-Modules no load,
full voltage. It is thus utterly advisable to
Never touch uninsulated cables(ends),only use electric
section is adequate for the PV module operating currents. Connections
sequence as described below.
Warning: High pressure danger! Solar cell modules may produce a high open circuit voltage,
to disconnect the circuit breaker or fuse before wiring, the wiring process must be careful.
WARNING: Risk of explosion! In case the battery's positive and negative terminals or leads
get ever in touch, i.e. short-circuited, a fire or explosion hazard might get triggered.
Always pay maximum when handling batteries and related circuits.
The load end is prohibited from accessing the inductive load.
CAUTION:
1.Should the temperature sensor be short-circuited or damaged, the controller
can charge or discharge the battery at the default 25 ºC.
2.If a power inverter is used the system, it should be connected to the battery
via a DC relay. Do not connect it to the controller's load terminals.
1st step: Connect loads
Connect the load cable with the correct polarity of the right-hand side pair of terminals on the solar
charge controller(with the lamp symbol). To avoid the presence of any tension on the cable/wires, please
connect these first to the load
2nd step: Connect the battery
Connect the battery cable to the two terminals in the middle of the controller with the correct polarity
(the controller is marked with the battery icon).
1)Should your system be nominal 12 Vdc, make sure the battery voltage is between the 10.0and 15.0 Vdc
voltage range;
2)For 24 Vdc nominal voltage, the battery voltage should be within the 20.0 to 30.0 Vdc range;
If the polarity is correct, the LCD on the controller will begin to display those.
3rd step: Connect the solar module
When connecting the PV-Module make sure to cover it from incident sun light. Double check the PV-
Module will not
exceed the maximum permissible input current of the Charge Controller (please refer to
the section Technical Date). Connect the solar module connection cable to the correct polarity of the left
pair of terminals on the solar charge controller (with the solar module symbol).
4th step: Final work
Tighten all cables connected to the controller and remove all the remains around the controller (leaving
avoid of minimum 15 cm).
4.2 Grounding
Be aware that the positive terminals of controller are interconnected and therefore bear the same electrica
potentia. If anyl grounding is required, always do this on the positive wires/terminals.
protect PV-modules from any incident light during installation;
⑤
⑥
③
before connecting them to the charge controller.
Page 2 of 10 pages
insulated tools, and make sure that the wire cross
must always be
②
①
Relay
④
Inverter
conducted in the