Preliminary checks
Remove the Altivar 16 from its packaging and check that it has not been damaged in transit.
Check that the reference of the speed controller on the label is the same as that on the delivery note and
corresponds to the order form.
Reference code
9572400449756
Example : ATV-16U09 M2
Choice of speed controller
Power supply
voltage
208 / 240 V
- 10 % + 10 %
50/60 Hz ± 2 Hz ATV-16 U18M2 0.75
Single phase
208 / 240 V
- 10 % + 10 %
50/60 Hz ± 2 Hz ATV-16 U41M2
Single/Three phase
400 / 460 V
- 15 % + 15 %
50/60 Hz ± 2 Hz ATV-16 U29N4
Three phase
(1) Line current : the values shown correspond to the current drawn by the speed controllers on a low impedance
supply, under rated load and speed conditions of the motor.
(2) Transient current : for 60s.
The Altivar 16 is designed to supply the required power for each of these motor sizes.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Altivar 16
power rating :
U09 : 0.9 kVA
U18 : 1.8 kVA
U29 : 2.9 kVA
U41 : 4.1 kVA
U54 : 5.4 kVA
U72 : 7.2 kVA
U90 : 9.0 kVA
Reference
Motor
power
rating
kW
ATV-16 U09M2 0.37
ATV-16 U29M2
1.5
2.2
ATV-16 U18N4 0.75
1.5
ATV-16 U41N4
2.2
ATV-16 U54N4
3
ATV-16 U72N4
4
ATV-16 U90N4
5.5
Power supply
voltage :
M2 : 208 / 240 V
N4 : 400 / 460 V
Sp. contr. Maximum
Line
rated
current
current
(1)
(In)
HP
A
A
0.5
4
2.1
1
7
4
2
14 /10
7.1
Single/Three
3
18 /14
10
Single/Three
1
3.3
2.3
2
6
4.1
3
9
5.8
4
12
7.8
5
16
10.5
7.5
20
13
Total power
transient
dissipated at
current
rated load
(2)
A
W
3.2
22
5.4
35
10
55
14
65
3.1
35
5.5
50
7.9
70
11
100
14.2
135
17.6
185
E
N
G
L
I
S
H
17