Akron FIREFOX 3293 Instrukcja obsługi - Strona 3
Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Jednostka sterująca Akron FIREFOX 3293. Akron FIREFOX 3293 11 stron.
Your nozzle should be inspected prior and after each use, to ensure it is in good operating
condition. Periodically, an unanticipated incident may occur where the nozzle is used in a
manner that is inconsistent with standard operating practices and those listed in IFSTA. A
partial list of potential misuses follows:
There are many "tell-tale" signs that indicate nozzle repair is in order, such as:
If any of the above situations are encountered, the nozzle should be taken out of service
and repaired, plus tested by qualified nozzle technicians, prior to placing it back in service.
OPERATING INSTRUCTIONS
• To change the spray angle, push the toggle switch to either SS (straight stream) or fog.
• To change the flow on an adjustable flow version, you must shut off the flow, adjust the spray pattern past fog
until it stops, then manually push the baffle head in and rotate it until the roll pin aligns with the desired flow
setting. For fixed flow versions, the baffle head must be removed, and the flow spacer changed for the desired
flow. The flow options and spacer information can be found on the parts list.
• To flush the nozzle, push the toggle switch towards the fog position until it stops. This gives you the maximum
orifice for clearing small debris. (30-125 gpm nozzle only)
MAINTENANCE
• Under normal conditions, periodically flushing the nozzle with clean water and cleaning grit and dirt from around
exterior moving parts will allow the nozzle to operate as designed.
• Over time the seals and turbine teeth may need to be replaced. This can be accomplished by purchasing the
appropriate Akron repair parts. Use Qualified maintenance mechanics or return the nozzle to Akron Brass for
repair.
WARRANTY AND DISCLAIMER: We warrant Akron Brass products for a period of five (5) years after purchase against defects in materials or workmanship. Akron Brass will repair or replace product
which fails to satisfy this warranty. Repair or replacement shall be at the discretion of Akron Brass. Products must be promptly returned to Akron Brass for warranty service. We will not be
responsible for: wear and tear; any improper installation, use, maintenance or storage; negligence of the owner or user; repair or modification after delivery; failure to follow our instructions or
recommendations; or anything else beyond our control. WE MAKE NO WARRANTIES, EXPRESS OR IMPLIED, OTHER THAN THOSE INCLUDED IN THIS WARRANTY STATEMENT, AND WE DISCLAIM ANY
IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. Further, we will not be responsible for any consequential, incidental or indirect damages (including, but not
limited to, any loss of profits) from any cause whatsoever. No person has authority to change this warranty. Unless otherwise provided herein. Akron Brass industrial electronic components & the
Severe-Duty Monitor have a one (1) year warranty. Select Akron Brass handline nozzles and valves carry a ten (10) year warranty. Weldon products have a two (2) year warranty from date of
manufacture (excluding consumable components). Select Weldon LED products carry a five (5) year warranty. Honda products have the manufacturers' warranty and Akron Brass disclaims any
warranty in respect of those products.
PHONE: 800.228.1161 | WEBSITE: www.akronbrass.com
Sheet: 119695
STYLE 3293 FIREFOX
OPERATING INSTRUCTIONS
• Operating above maximum rated pressure and flow.
• Not draining and allowing water to freeze inside the nozzle.
• Dropping the nozzle from a height where damage is incurred.
• Prolonged exposure to temperatures above +130 degrees F, or below -25 degrees F
• Operating in a corrosive environment.
• Other misuse that might be unique to your specific firefighting environment.
• Controls that are either inoperable or difficult to operate.
• Excessive wear.
• Poor discharge performance.
• Water leaks.
Revision 09/2022
NOZZLES
™
Page: 3 of 11