PODIUM MOUNTED AUTOMATIC GEL HAND SANITIZER DISPENSER (HSD) INSTALLATION GUIDE (Pg 1 of 4)

INSTALLATION

1. Install spout and sensor housing with escutcheon flange, rubber washers and basin nut (supplied)
through 1" Dia. [Ø25] mounting hole. (see Fig. 1)
2. Fix the pump to the desired location by securing the bracket with two (2) № 8-32 x 1/2" self-threading Phillips
FH stainless steel screws (provided) or hardware to suit site conditions.
COM CABLE NOT SHOWN FOR CLARITY
3. Connect flex tubing from dispenser shank to fitting on top of pump/control housing. Ensure square cut if
shortening tube from supplied length and completely insert into connector until hard stop with firm push
4. Connect spout Com-cable plug into control unit inline cable connector.
Note: Com plug should be inser ted fully so that the white O-ring is not visible and a clicking sound is
heard. If Com plug is not connected properly, the motor will run continuously. (see Fig. 3)