DESCRIPTION OF THE UNIT
The FCW fan coil for wall mounting is a concentration of
top level technological and functional features that make it
the ideal climate control unit for all environments.
The supply of climate controlled air is immediate and
distributed throughout the room; FCW generates heat if
included in heating system with boiler or heat pump but it
may also be used in the summer as an air conditioner if the
system has a water chiller.
MAIN CHARACTERISTICS:
• Three-way water valve incorporated inside it
• EUROVENT Certified
• PANTONE colour Cool Grey 1C
• Choice between two different control models (it is not
possible to use the two models at the same time).
Infrared remote control unit (TLW1 accessory) with liquid
crystal display and support for the wall mounting. The
remote control unit enables all the unit's functions to be
controlled.
Wired remote panel (PFW accessory) with liquid crystal
display with supports to be affixed to the wall, four meter
cable. The panel makes it possible to control the main
functions of the unit.
The response to the commands is immediate if the
MAIN COMPONENTS
1 TLW1 (remote control unit) accessory
2 Support for the wall mounting of the TLW1 remote control unit
3 PFW (wired remote panel) accessory
4 Front panel
5 Horizontal air delivery deflector fin
6 Air filter
FCW 21 - 31
4
5
6
7
8
9
TLW1
HR
environmental temperature and the temperature of the water in
system so allow;
- Three-speed cross flow fan
• Very quiet operation
•High-design appearance with rounded lines
• Air delivery slats with horizontal adjustment facility
• Motorised horizontal air delivery deflector that may be
worked with both the remote control unit or the wired
remote control unit for the vertical directioning of the output
air with continuous or fixed oscillation that can be selected
among the four pre-established positions or any other
position as required
• Microprocessor control
• Timer for the programming of the turning on or off
• Automatic functioning programme, cooling, heating,
ventilation and dehumidification (only with TLW1 remote
control unit)
• Automatic season change
• Automatic restart after power outage
• Ease of installation with plumbing connections and
condensate drain that can be pointed in several directions
Routine maintenance is limited to periodic cleaning of the
air filter.
- Full compliance with safety regulations.
7 Heat exchanger battery
8 Three-way water valve
9 Fan unit
10 Receiver
11 Lit indicators (LED)
12 Auxiliary emergency switch
10
2
1
12
11
PFW
3
8