Installation instructions
Connecting the exhaust duct to the
Left or Right Side Outlet
To connect the exhaust duct to the left or right
side outlet, follow the steps below:
1. Using a fl athead screw-driver, turn the
exhaust outlet cover you plan to use to the
right or left to align the tabs holding the cover
in place.
2. Remove the exhaust outlet cover.
3. Remove the stub pipe from the rear exhaust
outlet and place it in the outlet you plan to
use.
4. Push the duct onto the stub pipe and secure
it with a clamp.
5. With the duct attached, insert the stub pipe
into the hole. It should snap into place.
6. After you push the dryer into place, check for
kinks in the duct.
7. Use the exhaust outlet cover you removed
from the to cover the rear exhaust outlet.
WARNING!
To reduce the risk of fi re, this appliance must
be exhausted OUTDOORS or the equivalent.
Never cover the end of the dryer stub or exhaust
duct with anything to catch lint, except for UL
approved vent basket.
6
Connecting to a ventilation duct
You will need a UL-CSA-approved, 4-inch
ridged metal exhaust duct. If a fl exible duct is
used, it must comply with the Outline for Clothes
Dryer Transition Duct. Subject 2158A and
maximum length of 2.4 m (8 feet).
NOTE!
The more bends and the longer the duct, the
less air will circulate through the machine,
which will impede drying performance. We
recommend that you cut off any excess exhaust
duct and run the duct with as few bends as
possible. And make any necessary bends as
gentle as possible.
NOTE!
Maximum duct length of 60 feet. A maximum of
4 elbows may be used, but 4 feet of duct must
subtracted from the total vent length for every
90° elbow used.
NOTE!
When installing in warm climates (77° F and
above) with high humidity levels, do not route
the air exhaust duct upwards.
Customer Care Center
1-800-898-1879
www.askona.com
Examples of
installations
subtract 4
feet for every
90° elbow