For the fitter
6,4

Choice of location

Your appliance should be positioned so
that the mains switch is accessible. The
distance between the edge of your
appliance and the side and rear walls (or
partitions) must be at least four centimetres
(area A).
Your appliance can be easily integrated
above a cabinet, an oven or a build-in
household appliance. You must simply
ensure that the air intakes and air outlets
are clear (See "Description of Your
Appliance" section).

Build-in

Follow the diagram above.
Glue the foam seal underneath your
appliance by following the outline of the
worktop upon which your appliance will
rest. This will allow you to achieve an
airtight seal with the worktop.
To do this:
1
Follow the diagram above.
Glue the foam seal underneath your
appliance by following the outline of
Warning
You must ensure that the air intakes located under your cooking appliance remain
clear at all times. For all types of installation, your induction hob needs proper
ventilation.
14
58/77
49
A
51
56 /75
the worktop upon which your appliance will
rest. This will allow you to achieve an airtight
seal with the worktop.
2
Attach the clips to the hob*.
*Depending on model
Tip
If your oven is located below your hob, the
hob's thermal safety measures forbid the
simultaneous use of the hob and the
pyrolysis program of your oven.
Your hob is equipped with an anti-
overheating safety device.
This safety can be activated, for example,
when the hob is installed over an oven that
is not sufficiently insulated. If this occurs, a
series of small lines appear in the control
panel. In this case, we recommend that
you increase the ventilation of your hob by
creating an opening in the side of your
cabinet (8 cm x 5 cm) and/or you can also
install the oven insulation kit that is
available from the After-Sales Service
Department.
On 80cm models, ensure that the unit
cross member is not blocking air
passage. If necessary, make a
chamfer.