ASKOHEAT‐
FO
Circuit diagram
WARNING!
1.0 to 10.0 kW (type A)
AHFOR-BI-A-...
AHFOR-B-A-...
12.0 to 18.0 kW (type E)
AHFOR-BI-E-...
AHFOR-B-E-...
ASKOHEAT‐
_180_1-18_en
FO
Flange heater Ø 180 mm
All power supply circuits must have been switched off before accessing
the connec on terminals .
MVGASV_160101_en_V3
O p e r a t i n g v o l t a g e :
- L/N
230 V ~ (1.0 - 3.0 kW)
» Insert jumper L1‐L2‐L3 for 230 V~!
- L1/L2/L3
400 V 3~ (1.0 - 3.0 kW)
» The neutral conductor (neutral point) may not be
connected for 400 V~!
» The regula ons of the local electrical power u li‐
es must be complied with!
O p e r a t i n g v o l t a g e :
- L1/L2/L3
400 V 3~ (4.0 - 10.0 kW)
» The regula ons of the local electrical power u li‐
es must be complied with!
O p e r a t i n g v o l t a g e :
- L/N
230 V ~ (control voltage)
- L1/L2/L3
400 V 3~ (power)
» The power contactors must be fi ed by the
customer!
» The regula ons of the local electrical power u li‐
es must be complied with!