Ducted Options.
6.1 Ducted flue gasses
The products of combustion can be taken away
from the room where the product is being used by
the use of a flue duct.
To keep touch and floor temperatures to an
acceptable level, Ambi-Rad recommend a twin
wall flue pipe with a 108mm diameter capable of
withstanding 175°C. A total length of 10m must be
used.
Ambi-Rad can supply the 5m ducted flue kit by
quoting part no. 200584. A 5m extension kit is
also available by quoting part no. 200601.
Care must also be also taken by the user to
ensure that any potentially combustible materials
do not come into contact with the flue pipe.
A flue pipe connection is available from Ambi-Rad
to connect to the flue pipe on request.
Firstly, attach the front flue pipe section to the
product by pushing the flue duct spigot into the
flue outlet to ensure that the spring loaded flap
moves through 90° to close off the flue outlet to
the axial fan air stream.
Secondly, attach the rear flue pipe section at the
end of the front section as shown above. The
securing clip can now be tightened to keep both
sections together.
6.2 Ducted air
IMPORTANT In environments where
dust, moisture or fumes are present a
ducted air inlet is provided to allow
fresh air to be drawn into the burner to aid
combustion and prevent obstruction of the
burner with foreign objects. The tube feeding
the ducted air inlet must be 150mm diameter
and have a maximum length of 10 metres.
Ambi-Rad can supply a 5m ducted air spigot kit by
quoting part no 201847.
To fit the ducted air tube assembly push the
ducted air spigot into the connection point on the
side of the product as shown in the above photo.
6.3 Air delivery duct
A 450mm air delivery duct can be fitted to the
outlet spinning as shown using a suitable fixing
method. A material capable of withstanding 120°C
must be used.
Ambi-Rad can supply a 10m air delivery duct by
quoting part no 201848.
For Full installation details, please refer to
separate doc ref GB/TOR/175/1107.