Door Controls DC-ONE V3 Manual de iniciação e resolução de problemas - Página 8
Procurar online ou descarregar pdf Manual de iniciação e resolução de problemas para Controlador Door Controls DC-ONE V3. Door Controls DC-ONE V3 13 páginas. Automatic door controller
If door is not dragging or binding, reset the torque setting in the
programming. Start by raising the LEARN torque setting by 10%,
Then raise the values of OPEN / CLOSE, OPEN / CLOSE
CHECK TORQUE By 10%. Do this until the door moves properly.
Breakout switch is not wired properly. If red light is on for
breakout function on I/O interface, it means that the control is
in a breakout condition. Check to ensure breakout polarity is
set correctly.
On/Off switch is not wired properly or it is in the off position. If
the switch is in the on position, the green LED to the left of the
display will be on.
Important
Upon completion of your retrofit, ensure all functions of the door
perform satisfactorily. Walk-test the door according to AAADM
recommended guidelines and correct all discrepancies, if any, before
leaving the job site. DO NOT compromise proper performance. If
repairs cannot be immediately made, shut the door OFF and inform the
owner of any special instructions and corrective actions.
I/O CONNECTOR LAYOUT AND DESCRIPTION
J6
1
x
Common +
2
x
Off
3
x
One Way
4
x
Partial Open
5
x
Hold Open
6
x
Reset
7
x
24 VAC
8
x
24 VAC Return
9
x
Common +
10
x
Safety
J5
1
x
24 VAC
2
x
24 VAC Return
3
x
Common +
4
x
Inner Sensor
5
x
24 VAC
6
x
24 VAC Return
7
x
Common +
8
x
Outer Sensor
9
x
Safety
10
x
Common +
J7
1
x
Common +
2
x
Emergency Open
3
x
Common +
4
x
Ratchet
5
x
Common +
6
x
Activation
7
x
Common +
8
x
Breakout
9
x
Common +
10
x
Night Mode
J8
1
x
SOLENOID -
2
x
DC One Lock
3
x
DC One Lock
4
x
DC One Lock
5
x
DC One Lock
6
x
SOLENOID +
7
x
NC
8
x
NC
9
x
NC
10
x
NC