SUPPORT SECTIONS (12S-8DM)
The chimney support section is a 4-strap 12" length of pipe. A chim-
ney support is required at the 30' level above fireplace after a straight
chimney run (see Figure 16). This support is designed to relieve extra
weight load on fireplace and elbows when high chimneys are installed.
30 FT.
Figure 16 - Support Sections
RT-8DM
Effective Height of
Termination Cap
14' Min.
Height
Standard Installation
10
VENTING INSTALLATION Continued
12S-8DM
Support
30 FT.
Return
Elbow
Effective Height of
Termination Cap
15' Min.
Height
2' Max
Pipe Length
Figure 17 - Typical Installation
www.Astria.US.com
RT-8DM
Alternate Installation
RT-8DM
Effective Height of
Termination Cap
Maximum
Height
60'
30E-8DM
126647-01A