f)
Especially for Figure e & Figure g mounting method, the modules may be mounted using
clamps designed for solar modules refer to Figure j, the modules must be supported along
the length of the edge, and should overlap the array rail by 10mm
g) Especially for Figure f & Figure g mounting method: the recommended mechanical load on
panels is less than 2400Pa, and this method is only suitable for 45mm frame module series.
4
Electrical Installation
4.1 Installation Condition
4.1.1 The electrical characteristics are
Pmpp under the standard test conditions (irradiance of 1000 W/m
Figure h
Figure i
Figure j
Figure k
14mm
2