10

Technical data

10.1

Technical data - electrical ratings

• Voltage supply:
• Consumption w/o load:
• Pulses per revolution:
• Phase shift:
• Duty cycle:
• Reference signal:
• Sensing method:
• Output frequency:
• Output signals:
• Output stages:
• Interference immunity:
• Emitted interference:
• Approvals:
10.2

Technical data - mechanical design

• Size (flange):
• Shaft type:
• Admitted shaft load:
• Flange:
• Protection EN 60529:
• Operating speed:
• Operating torque typ.:
• Rotor moment of inertia:
• Materials:
• Operating temperature:
• Resistance:
• Corrosion protection:
• Explosion protection:
• Connection:
• Weight approx.:
MB058 - 11098546
Baumer_OG90_DE_EN_202209_MI_11098546 (22A3)
9...26 VDC (HTL- version C, TTL - version R)
5 VDC ± 5 % (TTL)
≤100 mA
1024...10000 (as ordered)
90° ±20°
40...60%
Zero pulse, width 90°
Optical
≤250 kHz
K1, K2, K0 + inverted
HTL-C
TTL/RS422
(as ordered)
EN 61000-6-2
EN 61000-6-3
CE, UL
ø115 mm
ø11 mm solid shaft
≤80 N axial
≤100 N radial
EURO flange B10
IP55
≤12000 rpm (mechanical)
1 Ncm
40 gcm
2
Housing: aluminium die-cast
Shaft: stainless steel
-30...+85 °C
Restricted in potentially explosive environments, see section 2.
IEC 60068-2-6
Vibration 10 g, 10-2000 Hz
IEC 60068-2-27
Shock 100 g, 1 ms
IEC 60068-2-52 Salt mist
complies to ambient conditions C4
according to ISO 12944-2
II 3 G Ex ec IIC T4 Gc (gas)
II 3 D Ex tc IIIB T135°C Dc (dust)
(only with option ATEX)
Terminal box
1.5 kg
10
Technical data