6) Specifications
General Specifications
Display: 3-3/4 digits 4000 counts, dual LCD displays
Update Rate: 3 per second nominal
Polarity: Automatic
Low Battery Indication: Below approx. 2.4V
Operating Temperature: 32°F to 104°F (0°C to 40°C)
Relative Humidity: Maximum relative humidity 80% for temperatures up to 88° F (31°C)
Altitude: Operating below 6,562 ft (2000m)
Storage Temperature: -4°F to 140°F (-20°C to 60°C), < 80% R.H. (with battery
Temperature Coefficient: nominal 0.09 x (specified accuracy)/°F @ 32°F - 64°F or
Sensing: Average sensing
Power Supply: Two 3V alkaline button batteries (ANSI/NEDA-5004LC, IEC-CR2032).
Battery Life: 95 hours approx. (in DCV mode)
Power Consumption: 2.5 mA typical
Low Battery Indication: Below approx. 2.4V (battery symbol appears in upper right)
Auto Power Off: After being idle for 30 minutes
APO Consumption: 0.8µA typical except 25µA typical for temperature function
Dimension: L 7.48" X W 2.48" X H 1.25" (L190mm X W 63mm X H 32mm)
Weight: 0.450 Lb approx. (204 g)
Jaw opening & Conductor diameter: 1.02" max (26mm)
Standard Accessories:
Test leads (pair), banana plug style, bead Type-K Thermocouple, batteries (installed),
user's manual, & soft carrying pouch
Replacement Part Numbers:
Test Leads (pair): MTL-90B, Bead Type-K Thermocouple: TPK-59, Carrying Case:
SV-U
Safety:
Meets IEC61010-2-032(1994), EN61010-2-032(1995), UL3111-2-032(1999).
Category III 600 Volts AC & DC
CE Approved
UL Listed
Transient protection: 6.5kV (1.2/50µs surge) for all models
Pollution degree: 2
decreasing linearly to 50% relative humidity at 104° F (40°C)
removed)
82°F - 104°F (0°C - 18°C or 28°C - 40°C), or otherwise
specified