Drazice PTO 1733 Manual de operação e instalação - Página 8

Procurar online ou descarregar pdf Manual de operação e instalação para Aquecedor Drazice PTO 1733. Drazice PTO 1733 14 páginas. Little flow heaters

Close the main water inflow. Screw a low-pressure combination faucet with a decorative rosette on the
water inlet neck G 1/2". Seal the threads on the water inlet. Insert sealing rings into the outlet terminals
of the faucet. Loosen 2 screws fastening the cover on the sides of the flow heater so that the thrust
bottoms in the holes on the rear side created a space for sliding in the attached holder. Mount on the
holder. Mount the flow heater preliminary on the combination faucet and evenly tighten the alligator nuts
using wrench No 16. Mark holes for wall plugs on the side. Disconnect the flow heater from the faucet.
Bore the marked holes on the wall with a 8 mm drill bit into the depth of 40 mm. Place the wall plugs
into the hole and fix the holder with two spiral dives. Insert a sieve into the flow heater cold water inlet
marked with an arrow, unless this has already been done by the manufacturer. Put the heater on the
fastened holder and tighten the 2 screws on the sides of the flow heater. Connect the combination faucet
by even tightening of the alligator nuts. Before opening the main water closure, unscrew the pearlator
on the drain arm or the shower saver.
First open the cold water valve on the combination faucet to let contaminated water flow
out. Open the hot water valve and bleed the flow heater.
Mount the pearlator on the drain arm only when clean and bled water flows out. After that, the appliance
can be connected to power supply.

2.1.2 LOW INSTALLATION

Close the main water inflow. Fasten the combination faucet under the hand basin or the sink. Connect
the cold water pipe (hose) of the combination faucet to the corner valve of cold water inlet. The corner valve
outlet must have thread 3/8". Mount the flow heater on the wall in the same manner like for the elevated
installation. The inlet and outlet of the heater must be directed upwards. When fixing the heater make
sure the distance for connecting the inlet and outlet pipe (hose) of the combination faucet is sufficient.
Connect the cold water inlet and outlet pipe (hose) of the combination faucet to the heater as indicated
by colour arrows. Before tightening the alligator nuts insert a sieve in the cold water supply pipe - unless
the manufacturer has already done so. Open the main water lock.
Figure 3
- 8 -