INSTALLATION
FREE STANDING STOVE CLEARANCES
A stove must never be installed in a hallway or near a staircase,
since it may block the way in case of fire or fail to respect required
clearances. It is of utmost importance that the clearances to
combustible materials be strictly adhered to during installation of
the stove. Refer to the tables below. Do not place any combustible
material within 1.2m of the front of the unit.
Combustible Back Wall
Combustible Back Wall
Backwall
DIMENSION
A
B
C
D
E
F
These stoves can be installed with a clearance of 50mm to non
combustible material
If this reduced clearance installation is
performed, it is critical to respect the clearances to any combustible
materials in the proximity of this installation. Combustible materials
6720818040 B 04/2017
Backwall
Backwall to Stove
Sidewall to Stove
Wall to corner (Angled Installation)
Backwall to Flue
Sidewall to Flue
Wall to Flue (Angled Installation)
The clearance between the flue pipe and a wall are valid only for
vertical walls and for vertical flue pipe.
The chimney connector must not pass through an attic or roof
space, closet or similar concealed space, a floor, or a ceiling.
A flue pipe crossing a combustible wall must have a minimum
clearance of 457mm.
CORNER INSTALLATION
CORNER INSTALLATION
Bewdley 3
Bewdley 5
300mm
300mm
400mm
400mm
300mm
300mm
353mm
353mm
513mm
548mm
353mm
353mm
could include, but not be limited to, paint or a finish material on
the non-combustible materials. Combustible materials would
include these materials coming in contact with the non-combustible
materials.
Backwall
Backwall
Combustible
Combustible
Back Wall
Back Wall
Bewdley 8
350mm
350mm
350mm
394mm
534mm
394mm