ATIGO A901S Manual de instalação - Página 4
Procurar online ou descarregar pdf Manual de instalação para Sistema de intercomunicação ATIGO A901S. ATIGO A901S 5 páginas. 2 wire kit
Setting panel status indicators
All status indicators are set to ON as default
•
door unlocked, LED + Voice
•
calling, LED + Voice
Programming
1. Power OFF door panel
2. Set DIP switch 6 to ON position
3. Power back ON door station and press call
button within 10 seconds to enable
programming mode.
System will exit programming mode
automatically after 10 seconds, if not in use.
LED status setting
Voice status setting