AirTech ACR35CV Instruções de instalação e cablagem - Página 3
Procurar online ou descarregar pdf Instruções de instalação e cablagem para Ventilador AirTech ACR35CV. AirTech ACR35CV 13 páginas.
DESCRIPTION
The fan is a continuously running extract fan for kitchens, utility rooms, bathrooms and
toilets.
The product incorporates an airflow detection system that detects the installation duct
resistance and maintains the correct fan speed to achieve the preset extract flow rate
(model dependant).
The incorporated LED display allows the installer to configure the fan to suit its
installation. The display is also used to show the day logger and power run meter.
The fan can be wall, window or panel/ceiling mounted.
ACCESSORIES
WALL KIT stock ref. – ESG100WALL
WINDOW KIT stock ref. - AWK100
CEILING KIT stock ref. - ACKS100
150mm CONVERSION KIT stock ref. - ACR-CK46
INSTALLATION
PANEL/CEILING MOUNTING
1.
Cut a 105mm diameter hole.
2.
Remove the front panel by carefully
pulling away from the fan.
3.
Loosen the two self-retaining screws and
remove the inner grille by carefully pulling
away from the housing.
4.
Using the built in spirit level bubble as an
aid. Mark the screw centres through the
holes in the fan back plate. Drill, plug and
screw into position. Attach ducting as
required for the installation.
5.
Wire the fan as described in Wiring
Section. Adjust any settings as required (see
Setup Section).
6.
After installation, ensure impeller rotates freely.
7.
Replace the inner grille and tighten the retaining screws. Replace the front panel.
WALL MOUNTING
1.
For wall mounting cut a 117mm diameter hole through the wall and insert the
wall sleeve. Slope the sleeve slightly downwards away from the fan. Where
necessary cut to length and cement both ends into position flush with the wall
faces.
2.
Fix exterior grille into position with the louvres positioned downwards.
3.
Remove the front panel by carefully pulling away from the fan.
4.
Loosen the two self-retaining screws and remove the inner grille by carefully
pulling away from the housing.
5.
Using the built in spirit level bubble as an aid.Mark the screw centres through the
holes in the fan back plate. Drill, plug and screw into position.
6.
Wire the fan as described in Wiring Section. Adjust any settings as required (see
Setup Section).
6.
After installation, ensure impeller rotates freely.
7.
Replace the inner grille and tighten the retaining screws. Replace the front panel.
Open up the internal cover to access
The spirit level bubble