Airthereal EVT-9K Manual do utilizador - Página 8

Procurar online ou descarregar pdf Manual do utilizador para Aquecedor de água Airthereal EVT-9K. Airthereal EVT-9K 16 páginas. 9kw electric tankless water heater
Também para Airthereal EVT-9K: Manual do utilizador (19 páginas)

Airthereal EVT-9K Manual do utilizador

INSTALLATION INSTRUCTIONS

QUICK START GUIDE
1. Fix the mounting bracket on the back of the machine with locking screws.
2. Mark mounting holes on the wall. Drill pilot holes of ¼ inch diameter. Put expansion bolts into the
holes, then screw the self tapping screws into the expansion bolts to attach the mounting hook.
Attach the machine to the mounting hooks.
Mounting
Hook
8.82 inch
3. Run a set of 8AWG/2 wires to the unit's 2 hot lines and 1 Grounding wire for 240V power supply.
4. Connect the water pipe to the water inlet and water outlet connections. Please remember to use
a rubber seal ring.
5. Descaler device and manual shut-off valve(ball valve) are recommended to install in the cold
water line-in to get best performance and make future maintenance more convenient.
The use of a plug and socket is forbidden
40A Dolbe
Pole Breaker
Water
Outlet
Wall
Plug
Screw
L1 L2 E
Mesh Filter
Water
Inlet
Mounting
Bracke
Circuit Breaker Box
240V
L1
Hot Water Unit
L1
L2
Ground Bar
L2
7