ANSITE AST-2008D2 Manual do utilizador - Página 7

Procurar online ou descarregar pdf Manual do utilizador para Sistema de segurança ANSITE AST-2008D2. ANSITE AST-2008D2 10 páginas.

Press"9": exit telecommunications settings and hook on
Press"01": open guard zone one alarm reporting
Press"02": close guard zone one alarm reporting
Press"03": open guard zone two alarm reporting
Press"04": close guard zone two alarm reporting
Press"05": open guard zone three alarm reporting
Press"06": close guard zone three alarm reporting
Press"07": open guard zone four alarm reporting
Press"08": close guard zone four alarm reporting
If no key input more than ten seconds, the alarm system auto-dial will hook on and exit
telecommunicaton setting automatically.
If you press key "7" on your caller telephone ,you can monitor the sound given out around the
alarm set, but the monitor time is only lasted for 20 seconds when you press the key "7" one time.
If you want to continue to listen to the sound the ast-2008D alarm set, you have to press the key
"7" again on your caller telephone not more than 20 seconds interval.
Installation and use guid Infrared detector installation and use
Open the power swith on the side of the detector at first. Mounting height is adjust to 2.2m or so.
Mounted on the corner of the room is preferable, and its detecting direction prependicular to
people walking direction will have best effect.
Mounting method: take out the bracket in the accessories and fix it on your wall, fix the detector
to the bracket and adjust its detection angle to best position. The following aspect should be noted:
1. the infrared detector may not direct to outward window
2. odstacle on its front have negative effect
3. more than two infrared detectors should not indtalled on the same area
4. strong wind flow, fire, radiator should be avoided, for it may trig wrong alarm message
5. when the infrared detector powered up, it will take five minutes to adapt itself to working
mode
6. the infared detector can only used in closed room, not used in open ground.
Door entry detector(magnetic swith & emittr) installation and use
1. The emitter of door entry detector is mounted on the edge of moveable door, and the magnetic
bar is mounted on the fixed doorfram. The two pieces of devices must be not more than 1cm
distance when the door closed.
2. The magnetic bar must be installed near to the emitter side of LED indicator.

ENCODING METHOD

Encoding and decoding method of the wireless alarm system
This alarm system use wireless transmission style to communicate with its wireless detectors. To