Anywire ARW-03 Manual do produto - Página 6
Procurar online ou descarregar pdf Manual do produto para Unidade Blu-ray Anywire ARW-03. Anywire ARW-03 17 páginas. Address writer
Também para Anywire ARW-03: Manual do produto do sistema (6 páginas)
[Precautions for use]
It is necessary to check the internal setting of the ARW-03 depending on the reading/writing unit.
Check the content of the setting memorized in this unit to match it with the target unit before use.
The following operations are necessary for correct setting in the target unit.
CAUTION
When using the address writer the first time, make sure to conduct the operations and check the content set in the writer.
If the matching of the address writer and unit is not correct and reading and writing operations are performed, it may cause the unit to
incorrectly operate. (If the setting is correctly adjusted again, that is not a problem.)
■Contents to be checked
The contents to be checked are the "maximum number of parameters to be selected" and "maximum points setting mode."
"Maximum number of parameters to be selected" is the number of parameters that can be set and is registered within
the range of "1 – 6."
For "maximum points setting mode," the maximum of address "256" or "512" that can be set is switched according to
the type of unit.
●Maximum points setting mode
Terminal connection
targets
Open Terminal Series
Bitty Brdge
EZwire
POKAYOKETERMINAL
A20 Series Master
■Setting operation
How to operate
Turn ON the POWER switch
1
pressing SELECT switch.
2
Press the UP switch once.
3
Press the SET switch.
Display the number to be set
by the UP/DOWN switches
4
to press the SET switch.
5
Press the L switch.
6
Press the DOWN switch once.
7
Press the SET switch.
Display the number to be set
8
by the UP/DOWN switches
to press the SET switch.
9
Turn OFF the POWER switch.
If moving to the address setting etc., turn ON the POWER switch again.
Use mode
256 mode
512 mode
○
ー
○
ー
●Maximum number of parameters to be selected
The maximum number of parameters is expressed as "Pn" and any number of 0 -
19 can be selected.
For example, if the maximum number is set to "4," 4 types (01 – 04) can be
selected in the parameter mode.
This parameter is selected based on the setting target unit and its necessary
setting function.
Normally, set the number to "19 (maximum)."
CAUTION
However, the parameters to be used vary depending on the slave unit.
Set only the parameter number to be used.
If unnecessary parameters are written, it may result in a malfunction.
or
~
~
Example)
or
or
-ARW03 6/17-
Display
Any number from 0 to 19
is displayed.
Dot flashing movement
After "SEt" is displayed,
the set value is
displayed again.
In the case of setting
the maximum number of
parameters to 19
Dot flashing movement
The display returns to that
of Operation No.1.
Dot flashing movement
After "SEt" is displayed,
the set value is
displayed again.
In the case of setting the maximum
address to 256
In the case of setting the maximum
address to 512